Suscribirse

Midterm outcomes allograft prosthetic composite reconstruction for massive bone loss at the elbow - 19/08/23

Doi : 10.1016/j.otsr.2022.103517 
Pierre Laumonerie a, , Joanna Granjou b, Meagan E. Tibbo c, Valentin Massin d, Nicolas Bonnevialle b, Pierre Mansat b
a Department of Orthopedics and Traumatology, hôpital Pellegrin, place Amélie Raba-Léon, 33000 Bordeaux, France 
b Department of Orthopedics and Traumatology, hôpital Pierre-Paul Riquet, Toulouse, France 
c Department of Orthopedics, Mayo Clinic, Rochester MN, United States 
d Department of Orthopedics and Traumatology, Institute for Locomotion, Marseille, France 

*Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Revision of a loose total elbow arthroplasty (TEA) is challenging, particularly in the context of massive bone loss (MBL). The use of an allograft prosthetic composite (APC) at the elbow is rare, typically reserved as a salvage procedure for MBL. Thus, limited data describing the outcomes of APCs are available in current literature.

Hypothesis

The authors hypothesize that short to midterm clinical outcomes of APC for MBL about the elbow are satisfactory.

Patients and methods

Between 2009 and 2018, 6 APCs implanted with a semi-constrained Coonrad Morrey prosthesis were performed in 5 females and 1 male. Median patient age was 70 years (range, 49–76 years). The indication for revision was aseptic loosening in all 6 cases (6 humeral and 2 ulnar). Median follow-up was 3.5 years (range, 2–6.7 years). Functional outcomes including Mayo Elbow Performance Score (MEPS), Visual Analog Scale (VAS), range of motion (ROM), and radiographic outcomes were assessed for all patients.

Results

Median MEPS and VAS scores were 75 (range, 40–90), and 0 (range, 0–8) at latest follow-up, respectively. Median postoperative flexion-extension and prono-supination arcs were 90̊ (range, 70–140̊) and 150 (range, 100–160̊), respectively. Allograft incorporation was noted in 5 (83%) patients; all prostheses were well-fixed. In total, 4 patients (63%) experienced 5 complications (83%) including periprosthetic fracture (n=2), ulnar neuropathy (n=1), aseptic loosening (n=1), and wound dehiscence (n=1). Two (33%) required reoperation with prosthetic retention.

Conclusion

Elbow reconstruction using allograft prosthetic composite is a viable option for patients with MBL following TEA. The midterm functional outcomes are satisfactory with no revisions required, despite a relatively high rate of complications. Further long-term studies with larger cohorts are needed to better elucidate long-term outcomes and reasons for failure.

Level of evidence

IV; therapeutic study (case series [no, or historical, control group])

El texto completo de este artículo está disponible en PDF.

Keywords : Allograft prosthetic composite, Massive bone loss, Elbow, Total elbow arthroplasty, Distal humerus

Abbreviations : TEA, MBL, APC, MEPS, VAS, ROM, MP


Esquema


© 2022  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 109 - N° 5

Artículo 103517- septembre 2023 Regresar al número
Artículo precedente Artículo precedente
  • Arthroscopic treatment of diffuse pigmented villonodular synovitis of the elbow
  • Pierre Lavignac, Paul Herraudet, Fabien Baudelle, Paul Commeil, Yohan Legallois, Thierry Fabre
| Artículo siguiente Artículo siguiente
  • Radial neck osteolysis after radial head replacement: Functional impact and risk factors
  • Maxime Antoni, Alexandra Bruyere, Nicolas Meyer, Philippe Clavert

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.