Suscribirse

Sympathetic and electrochemical skin responses in the assessment of sudomotor function: a comparative study - 14/04/23

Doi : 10.1016/j.neucli.2022.102840 
Juan Idiaquez a, , Juan Carlos Casar a, Ricardo Fadic a, Rodrigo Iturriaga b, c
a Department of Neurology, Faculty of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Chile 
b Department of Physiology, Faculty of Biological Sciences, Pontificia Universidad Catolica de Chile, Santiago, Chile 
c Universidad de Antofagasta, Antofagasta. Chile. 

Corresponding author at: Department of Neurology, Pontificia Universidad Catolica de Chile, 7 Norte 1122, Vina del Mar, Chile.Department of NeurologyPontificia Universidad Catolica de Chile7 Norte 1122Vina del MarChile

Abstract

Objectives

The sympathetic skin response (SSR) is a well-established test, whereas the electrochemical skin conductance (ESC) is still under evaluation. Our aim was therefore to assess the diagnostic accuracy of ESC to detect abnormal sudomotor function, using SSR as a reference test.

Methods

A cross sectional observational study was performed of 61 neurological patients assessed for possible sudomotor dysfunction and 50 age-matched healthy controls (HC). Patients with diagnoses of vasovagal syncope (VVS, n=25), Parkinson's disease (PD, n=15), multiple system atrophy (MSA, n=11) and peripheral neuropathies (PN, n=10) were included. Sudomotor function was assessed with SSR and ESC tests in all participants. The absence of SSR in the palms or soles indicates abnormal sudomotor function. Receiver operating characteristic (ROC) analysis was used to assess the diagnostic value of the ESC. Cardiovascular autonomic (CV-Aut) function was evaluated through the Ewing score, based on the following tests: Heart rate change with deep breathing, Valsalva ratio, 30:15 ratio, blood pressure changes on standing and during isometric exercise. A Ewing score ≥ 2 indicates the presence of CV-Aut dysfunction.

Results

Mean SSR amplitudes and ESC values showed differences between HC and patients with MSA or PN (p < 0.05), but not in patients with VVS or PD. Absence of SSR was associated with abnormal ESC (p < 0.05). Patients with abnormal CV-Aut dysfunction had lower ESC (p< 0.05). Palm ESC (P-ESC) and sole ESC (S-ESC) assessment had a sensitivity of 0.91 and 0.95 to predict sudomotor dysfunction, with a specificity of 0.78 and 0.85, respectively. The area under ROC curve was 0.905 and 0.98, respectively.

Conclusions

ESC in palms and soles has a high diagnostic accuracy for sudomotor dysfunction as detected by absent SSR in patients with MSA and PN.

El texto completo de este artículo está disponible en PDF.

Keywords : Electrochemical skin conductance, Sudomotor, Sudoscan, Sympathetic skin response


Esquema


© 2022  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 53 - N° 2

Artículo 102840- avril 2023 Regresar al número
Artículo precedente Artículo precedente
  • Heart rate variability modifications in adult patients with early versus late-onset temporal lobe epilepsy: A comparative observational study
  • Fedele Dono, Giacomo Evangelista, Stefano Consoli, Romina Venditti, Mirella Russo, Maria Vittoria De Angelis, Massimiliano Faustino, Angelo Di Iorio, Catello Vollono, Francesca Anzellotti, Marco Onofrj, Stefano L. Sensi

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.