Suscribirse

D-dimer for assessment of treatment response, and survival to drug-eluting beads transarterial chemoembolization in hepatocellular carcinoma - 31/03/23

Doi : 10.1016/j.clinre.2023.102096 
Youjia Duan, Xiaopu Hou, Jiang Guo , Honglu Li, Liang Cai, Long Cheng, Wenpeng Zhao, Xihong Shao, Hongliu Du, Zhenying Diao, Changqing Li
 Department of Oncology Interventional Radiology, Beijing Ditan Hospital, Capital Medical University, No. 8 Jingshundong Road, Beijing 100015, China 

Corresponding author.

Highlights

Detection of D-dimer in hepatocellular carcinoma patients before and after DEB-TACE.
Elevated D-dimer level was related to tumor burden and poor liver function.
High levels of D-dimer estimated lower complete response to DEB-TACE therapy.
High levels of D-dimer could forecast shorter overall survival to some degree.
The D-dimer level was increased during DEB-TACE therapy.

El texto completo de este artículo está disponible en PDF.

Abstract

Background

D-dimer exhibits a certain prognostic value in hepatocellular carcinoma (HCC) patients who underwent hepatectomy and microwave ablation, while its value in estimating the clinical benefit of drug-eluting beads transarterial chemoembolization (DEB-TACE) remains unclear. Hence, this study aimed to investigate the correlation of D-dimer with tumor features, response and survival to DEB-TACE in HCC patients.

Methods

Fifty-one HCC patients treated with DEB-TACE were recruited. Their serum samples at baseline and after DEB-TACE were collected and proposed for D-dimer detection by the immunoturbidimetry method.

Results

Elevated D-dimer levels were related to a higher Child‒Pugh stage (P = 0.013), tumor nodule number (P = 0.031), largest tumor size (P = 0.004), and portal vein invasion (P = 0.050) in HCC patients. Then, patients were classified by the median value of D-dimer, and it was observed that patients with D-dimer >0.7 mg/L achieved a lower complete response rate (12.0% vs. 46.2%, P = 0.007) but a similar objective response rate (84.0% vs. 84.6%, P = 1.000) compared to those with D-dimer ≤0.7 mg/L. The Kaplan‒Meier curve showed that D-dimer >0.7 mg/L (vs. ≤0.7 mg/L) was related to shorter overall survival (OS) (P = 0.013). Further univariate Cox regression analyses showed that D-dimer >0.7 mg/L (vs. ≤0.7 mg/L) was related to unfavorable OS [hazard ratio (HR): 5.524, 95% confidence interval (CI): 1.209–25.229, P = 0.027], but it failed to independently estimate OS (HR: 10.303, 95%CI: 0.640–165.831, P = 0.100) in multivariate Cox regression analyses. Moreover, D-dimer was elevated during DEB-TACE therapy (P<0.001).

Conclusion

D-dimer may be helpful for monitoring prognosis to DEB-TACE therapy in HCC, while further large-scale-study validation is warranted.

El texto completo de este artículo está disponible en PDF.

Keywords : Hepatocellular carcinoma, Drug-eluting bead transarterial chemoembolization, D-dimer, Treatment response, Survival

Abbreviations : Hepatocellular carcinoma, Drug-eluting beads transarterial chemoembolization


Esquema


© 2023  The Authors. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 47 - N° 4

Artículo 102096- avril 2023 Regresar al número
Artículo precedente Artículo precedente
  • A case of peri‑stomal ectopic variceal bleeding in a patient with decompensated cirrhosis treated with TIPS placement
  • Giulia Iannone, Enrico Pompili, Matteo Renzulli, Paolo Caraceni
| Artículo siguiente Artículo siguiente
  • MAdCAM-1 does not play a central role in the early pathophysiology of autoimmune hepatitis
  • F.F. van den Brand, H. Masrati, E.S. Jordanova, E. Bloemena, B.I. Lissenberg-Witte, Y.S. de Boer, H.J. Bontkes, R. Mebius, G. Bouma

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.