Suscribirse

Are CPR (Contact Patch to Rim) distance anomalies associated with the occurrence of abnormal noises from ceramic-on-ceramic THA? - 01/02/23

Doi : 10.1016/j.otsr.2022.103438 
Jérémy Sarrazin a, b, , Marion Halbaut a, b, Pierre Martinot a, b, Sophie Putman a, b, Henri Migaud a, b, Julien Girard a, b, c
a Université de Lille, Hauts de France, 59000 Lille, France 
b Hôpital Roger Salengro, service d’orthopédie 2, CHU Lille, place de Verdun, 59000 Lille, France 
c Université de Lille, Université de Artois, Université Littoral Côte d’Opale, EA 7369 – URePSS – unité de Recherche Pluridisciplinaire Sport Santé Société, 59000 Lille, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The ceramic-on-ceramic couple in total hip arthroplasties (THA) has the advantage of excellent wear resistance and the bioinert nature of its debris. Noise occurring from this friction torque is a common complication, the contributing factors of which are debated. The noise is caused by a lack of lubrication, due in most part to the positioning of the acetabular cup. The study of metal-on-metal couples identified that the calculation of the Contact Patch to Rim (CPR) distance provides information on lubrication defects and also that it is correlated with the wear of metal-on-metal implants. This CPR distance is not recognized to be correlated with the occurrence of noise for the ceramic-on-ceramic couple at a caliber ≤ 36mm. We therefore conducted a retrospective case-control study to assess: 1) The influence of the CPR distance on noise occurrence; 2) Whether other factors associated to noise occurrence exist?

Hypothesis

Our hypothesis was that a low CPR distance was correlated with noise occurrence.

Method

This was a case-control study with 3 controls for each case, analyzing 21 THAs (21 patients) with noise compared to 63 THAs without noise (63 patients) matched for age, sex and body mass index. These patients were taken from a continuous retrospective series of 96 patients for 104 total hip arthroplasties (THA) with a single operator and 4th generation Biolox Delta ceramic-on-ceramic single implant, performed between 2007 and 2012. The calculation of the CPR distance was then performed for both groups using measurements of inclination angles, anteversion angles, and implant data regarding the head/insert contact angle, head/insert diameter and clearance.

Results

At the mean follow-up of 7.1 years±1.2 [5 to 9.6], the mean CPR distance was lower in the noise group 10mm±3.3 [3.8 to 16.4] than in the control group 14.8mm±4.3 [7.3 to 24.4] (p=0.0007). The mean inclination angle was higher in the noise group 45.1°±7.8 [31 to 62] than in the control group 41.2°±7.2 [26 to 56] (p=0.04). The occurrence of noise was independent of anteversion, head caliber, cup diameter, neck length and stem size, and stem type (standard or lateralized).

Conclusion

A low CPR distance was correlated with the occurrence of noises, similarly a steep inclination was correlated with the occurrence of noises.

Level of evidence

III; Retrospective case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty, Ceramic, Contact Patch to Rim distance, Squeaking, Noise


Esquema


© 2022  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 109 - N° 1

Artículo 103438- février 2023 Regresar al número
Artículo precedente Artículo precedente
  • Cementless metal-on-metal versus ceramic-on-polyethylene hip arthroplasty in under-50 year-olds with 20 to 22 years’ follow-up: Was it a good idea to abandon the small-diameter metal-on-metal bearing?
  • Matthieu Grélier, Pierre Martinot, Julien Dartus, Henri Migaud, Sophie Putman, Julien Girard
| Artículo siguiente Artículo siguiente
  • Wear rate and osteolysis in two types of second-generation annealed highly cross-linked polyethylene in total hip arthroplasty: A retrospective comparative study with a minimum of five years
  • Naoki Yamamoto, Ryohei Takada, Tetsuya Jinno, Kazumasa Miyatake, Naoto Watanabe, Hideyuki Koga, Toshitaka Yoshii, Kazuyoshi Yagishita, Atsushi Okawa

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.