Suscribirse

Wear rate and osteolysis in two types of second-generation annealed highly cross-linked polyethylene in total hip arthroplasty: A retrospective comparative study with a minimum of five years - 01/02/23

Doi : 10.1016/j.otsr.2021.103147 
Naoki Yamamoto, Ryohei Takada , Tetsuya Jinno, Kazumasa Miyatake, Naoto Watanabe, Hideyuki Koga, Toshitaka Yoshii, Kazuyoshi Yagishita, Atsushi Okawa
 Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

As no previous study has directly compared the linear wear rate in two types of second-generation annealed highly cross-linked polyethylene, we performed a retrospective study with a minimum of 5-year follow-up to assess primary arthroplasties in the (1) wear rates and (2) incidence of osteolysis of the two types of HXLPE.

Hypothesis

There was no significant difference in the linear wear rate and the incidence of osteolysis between the two types of second-generation annealed highly cross-linked polyethylene.

Patients and methods

In this single-center study, we reviewed 257 cases of primary cementless total hip arthroplasties between 2011 and 2015, which were performed with 32mm delta ceramic on second-generation annealed highly cross-linked polyethylene (X3 and E1 were used in 105 and 103 cases, respectively.). The mean wear rate was evaluated using a computer-assisted method, and the incidence of osteolysis was evaluated based on the appearance of a localized area with loss of trabecular bone or cortical erosion adjacent to the implants during the latest follow-up.

Results

In total, we evaluated 208 cases, followed postoperatively for over 5 years (mean, 6.1 years, range: 5.0-8.0). There were no significant differences between the two groups with respect to age (list in order of Group X, Group E, p value) (61.2±12.3, 62.7±12.1, p=0.36), sex (ratio of male: 17.1%, 14.6%, p=0.61), body mass index (22.9±3.7, 22.8±4.0, p=0.91), pre- (49.9±14.8, 48.5±13.8, p=0.49) and post-operative (91.3±9.1, 92.7±7.0, p=0.23) Japanese Orthopaedic Association Hip Score, cup size (50.8±3.0, 50.9±2.2, p=0.70), cup inclination (38.7±4.8, 37.6±4.8, p=0.10), and cup anteversion (18.7±6.9, 18.5±7.6, p=0.80). The mean linear wear rates of the X3 and E1 groups were 0.057±0.039 (range: 0–0.16) and 0.054±0.037mm/year (range: 0–0.15), respectively (p=0.61). No osteolysis was found on the final plain radiographs in both groups.

Discussion

This study revealed that both types of highly cross-linked polyethylene have excellent linear wear rates and were equally safe to use. However, the difference between the two materials in terms of the long-term wear rate should be further validated.

Level of evidence

III; retrospective case control study.

El texto completo de este artículo está disponible en PDF.

Keywords : X3, E1, PolyWare, Tapered-wedge, Cementless, Cross-linked polyethylene, Wear rate


Esquema


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 109 - N° 1

Artículo 103147- février 2023 Regresar al número
Artículo precedente Artículo precedente
  • Are CPR (Contact Patch to Rim) distance anomalies associated with the occurrence of abnormal noises from ceramic-on-ceramic THA?
  • Jérémy Sarrazin, Marion Halbaut, Pierre Martinot, Sophie Putman, Henri Migaud, Julien Girard
| Artículo siguiente Artículo siguiente
  • Liner type has no impact on bone mineral density changes around a 3D printed trabecular titanium acetabular component
  • Antonio Klasan, Ali Bayan, Ian Holdaway, William J. Farrington

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.