Suscribirse

Does acetabular robotic-assisted total hip arthroplasty with femoral navigation improve clinical outcomes at 1-year post-operative? A case-matched propensity score study comparing 98 robotic-assisted versus 98 manual implantation hip arthroplasties - 01/02/23

Doi : 10.1016/j.otsr.2022.103477 
Rémy Coulomb a, , Valentin Cascales a, Vincent Haignere a, François Bauzou a, Pascal Kouyoumdjian a, b
a Orthopedic and Traumatology Surgery Department, CHU Nîmes, University Montpellier 1, place du Professeur-Robert-Debré, 30029 Nîmes, France 
b Laboratory LMGC, CNRS UMR 5508, University of Montpellier II, Montpellier, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Despite the optimization of implant positioning, the clinical benefit of the use of robotic assistance during THA remains uncertain. In this case-control study (robotic versus manual technique) we made a retrospective short-term comparison of: (1) the functional results, (2) the complications, (3) and the influence of radiological symmetrization of the hips on the functional result.

Hypothesis

The use of a robotic arm improved the functional results of a THA.

Materials and method

A retrospective case-control study was performed, including patients with unilateral hip osteoarthritis who underwent a robotic arm-assisted THA (THA-R). The controls (THA-C) were matched according to age, sex, body mass index and surgical approach. The Harris (HHS), Oxford (OHS) and Forgotten Joint (FJS) scores were collected preoperatively and 1 year postoperatively. At each review, complications were categorized into minor events, revision surgery with and without implant change. Radiographic analysis was performed on weight-bearing images of the pelvis 3 months postoperatively. The objective of the surgery was symmetrization of the THA in the contralateral healthy hip. For each measured parameter of the hip joint center of rotation (COR), global offset (GO) and articular leg length discrepancy (aLLD), the difference between the two sides corresponding to the delta symmetrization was compared.

Results

Ninety-eight patients were included in the THA-R group and matched to 98 controls in the THA-C group. At 1 year postoperatively, the FJS and OHS scores were statistically higher in the THA-R group, respectively 82.1±22.3 [8.3; 100] and 40.8±8.8 [6; 48] vs. 71.2±27.8 [0; 100] and 38.1±9.7 [12; 48] in the THA-C group (p=0.004 and p=0.043). There was no difference in HHS (THA-R: 85.9±15.8 [31; 100] vs. THA-C: 85.8±13.3 [49–100] (p=0.962)). The implant revision rate at 1 year was significantly higher in the THA-C group (0% vs. 5.1% (p=0.025)). There was no difference in the reoperation without component exchange despite 3 dislocations (3.1%) in the THA-R group (5 (5.1%) vs. 9 (9.2%) (p=0.273)). The rate of abarticular pathologies (ilio-psoas irritation and greater trochanteric bursitis) was higher in the THA-C group (10 (10.8%) vs. 2 (2%) (p=0.016). Robotic acetabular assistance allowed a significantly better restitution of the horizontal position (THA-R: 1mm±4.8 [–11.7; 12.6] vs. THA-C: 4.1mm±7 [-29.6; 28] (p=0.0005)) and vertical COR (THA-R: 0.5mm±3.1 [–6; 8.3] vs. THA-C: 2mm±4.1 [–6; 14.6] (p=0.0068)). Navigated assistance of the femur did not significantly optimize the restitution of the Global Offset (THA-R: +2mm±6.4 [-16.4; 27.6] vs. THA-C: +0.5mm±7 .7 [–34; 30.2] (p=0.145)), or lower limb length (THA-R: +1.1mm±5 [–8.2; 13.5] vs. THA-C: +0.3mm±6 [-14.1; 22.5] (p=0.344). The FJS was statistically correlated with the restoration of the symmetry of the COR and the aLLD. A post-hoc power analysis confirmed sufficient potency (1-β=0.85).

Conclusion

Robotic acetabular assistance combined with femoral navigation improves clinical outcomes of THAs with fewer short-term complications. The precision of the positioning of the implants, optimized by the computer-assisted surgery system, is correlated with the missed joint score.

Level of evidence

III, retrospective case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : THA, MAKO, Forgotten joint score, Accuracy, Computer-assisted orthopedic surgery


Esquema


© 2022  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 109 - N° 1

Artículo 103477- février 2023 Regresar al número
Artículo precedente Artículo precedente
  • Doctor, what does my ceramic-on-ceramic hip arthroplasty weigh?
  • Simon Marmor, Emmanuel De Panafieu, Antoine Mouton, Wilfrid Graff, Vincent Le Strat, Luc Lhotellier, Younes Kerroumi, Emmanuel Gibon
| Artículo siguiente Artículo siguiente
  • Combined kinematic cup alignment reduces the rate of impingement and edge loading compared to mechanical and anatomical alignment. An in-vitro case-control study
  • Thomas Aubert, Pierre-Alban Bouche

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.