Suscribirse

iQMetrix-CT: New software for task-based image quality assessment of phantom CT images - 03/11/22

Doi : 10.1016/j.diii.2022.05.007 
Joel Greffier a, 1, , Yves Barbotteau b, 1, François Gardavaud c, d
a IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France 
b Department of Radiology, CHP Clairval, Ramsay Santé, 13273 Marseille, France 
c Department of Radiology, APHP, Hôpital Tenon, 75020 Paris, France 
d Institute of Computing and Data Sciences (ISCD), Sorbonne Université, 75013 Paris, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlight

New iQMetrix-CT software was developed by a working group from the SFPM
This software calculates three advanced metrics, which are noise power spectrum, task-based transfer function and detectability index.
Noise power spectrum assesses noise texture and noise magnitude.
Task-based transfer function assesses spatial resolution as function to the noise and contrast.
Detectability index assesses the radiologist's ability to perform a given task such as lesion detection.

El texto completo de este artículo está disponible en PDF.

Abstract

The purpose of this article was to explain how the new iQMetrix-CT software works, as well as to describe its current potential and discuss its future applications. iQMetrix-CT was developed by a working group from the French Society of Medical Physicists (SFPM). This software calculates three advanced metrics, which have been adapted to take into account the non-linear and non-stationary properties of iterative reconstruction algorithms. Noise power spectrum is calculated to assess noise texture and noise magnitude in the frequency domain. The task-based transfer function is computed to assess the spatial resolution under conditions of contrast and noise similar to the lesions encountered in clinical practice. Finally, the detectability index is used to estimate the radiologist's ability to perform a given task such as detecting a simulated lesion. These metrics are very useful to evaluate the performance of reconstruction algorithms in term of image quality and optimize the doses of a given protocol or to evaluate and compare a new technology.

El texto completo de este artículo está disponible en PDF.

Keywords : Image quality, Computer-assisted image analysis, Multidetector computed tomography, Task-based image quality assessment, Software

Abbreviations : 1D, 2D, AAPM, CT, DLR, ESF, FFT, IR, LSF, NPS, NPW, ROI, TTF


Esquema


© 2022  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 11

P. 555-562 - novembre 2022 Regresar al número
Artículo precedente Artículo precedente
  • Reproducibility of apparent diffusion coefficient measurement in normal prostate peripheral zone at 1.5T MRI
  • Au Hoang-Dinh, Trung Nguyen-Quang, Lenh Bui-Van, Christelle Gonindard-Melodelima, Rémi Souchon, Olivier Rouvière
| Artículo siguiente Artículo siguiente
  • Serous cystadenoma mimicking cystic pancreatic neuroendocrine tumor on 68Ga-DOTATOC PET/CT
  • Goudarz T. Passand, Arthur Marichez, Frédéric Debordeaux, Jean-Baptiste Pinaquy, Laurence Chiche

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.