Suscribirse

Preoperative contrast-enhanced ultrasound (CEUS) of long bone nonunions reliably predicts microbiology of tissue culture samples but not of implant-sonication - 23/08/22

Doi : 10.1016/j.otsr.2021.102862 
Ulrike Dapunt a, b, 1, , Yina Zhao a, Gerhard Schmidmaier a, 1, Christian Fischer a, 1
a Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany 
b Ultrasound Center, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg, Germany 

Corresponding author at: Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany.Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University HospitalSchlierbacher Landstrasse 200aHeidelberg69118Germany

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Bacterial infection in the context of fracture repair remains a severe complication in trauma surgery and may result in long bone nonunion. Since treatment options for aseptic and infected nonunions vary greatly, diagnostic methods should ideally differentiate between these two entities as accurately as possible. Recently, contrast-enhanced ultrasound (CEUS) has been introduced as a preoperative imaging technique to evaluate hypervascularity at the fracture site as sign of bacterial infection.

Hypothesis

Preoperative CEUS predicts results of microbiological evaluation obtained either by culture of tissue samples or by analyzing the sonication fluid following removal and sonication of the implant.

Patients and methods

Over the course of 6 months, 26 patients with long bone nonunions were included in this study. Patients’ clinical data were evaluated. Tissue samples were collected intraoperatively and examined by standard microbiological techniques. The sonication method was applied to removed implants. Additionally, 1–3 days before surgery, CEUS was performed to determine hypervascularity at the nonunion site as a possible parameter for infection.

Results

Culture of tissue samples indicated infection in 50% of cases and implant sonication in 57.7% of cases. However, there was merely a fair agreement (κ=0.231) between these two diagnostic methods. CEUS predicted results of tissue culture reliably (sensitivity 92.3% and specificity 100%), whereas implant sonication showed no significant correlations with results from CEUS. Hypertrophic and atrophic nonunions were evaluated separately to determine possible differences in vascularity. We found that contrast peak enhancement of CEUS was similar in atrophic and hypertrophic nonunions with positive culture of tissue samples. Both differed significantly from culture negative cases (p=0.0016 and 0.0062). Results of implant-sonication positive or negative cases in atrophic and hypertrophic nonunions, however, were less clear and could be misleading.

Discussion

We were able to confirm CEUS as a valuable preoperative diagnostic tool that reliably predicts microbiology of tissue culture samples, but not of implant sonication.

Level of evidence

I; diagnostic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Long bone nonunion, Biofilm, Implant-associated infection, Sonication


Esquema


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 108 - N° 5

Artículo 102862- septembre 2022 Regresar al número
Artículo precedente Artículo precedente
  • Femoral shaft fractures treated by antegrade locked intramedullary nailing: EOS stereoradiographic imaging evaluation of rotational malalignment having a functional impact
  • Julien Boscher, Armand Alain, Guillaume Vergnenegre, Vincent Hummel, Jean-Louis Charissoux, Pierre-Sylvain Marcheix
| Artículo siguiente Artículo siguiente
  • Humeral shaft fracture: Outcomes of percutaneous antegrade intramedullary nailing using the long Telegraph® nail with dynamic distal locking
  • Amine El Ghazoui, Jamal Haddaoui, El Mostafa Zahar, Noureddine Sekkach

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.