Suscribirse

Sagittal reduction of spinal deformity: Superior versus lateral screw-rod connection - 29/10/21

Doi : 10.1016/j.otsr.2021.102954 
Solène Prost a, Sébastien Pesenti b, Kaissar Farah a, Patrick Tropiano a, Stéphane Fuentes a, Benjamin Blondel a,
a Aix-Marseille Université, APHM, CNRS, ISM, CHU Timone, Unité de chirurgie rachidienne, 264, rue Saint-Pierre, 13005 Marseille, France 
b Service de chirurgie orthopédique pédiatrique, Aix-Marseille Université, APHM, CNRS, ISM, CHU Timone, 264, rue Saint-Pierre, 13005 Marseille, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Spinal malalignment can greatly impact a patient's quality of life. Various sagittal parameters are used as realignment goals; however, about 50% of patients end up being under-corrected postoperatively. To improve the correction, prebent rods are available with a radius of curvature corresponding to the patient's “ideal” sagittal alignment. But no studies have been done on how the radius of curvature changes according to the type of connection between the pedicle screws and rods. The goal of this experimental study was to quantify how much prebent rods flatten based on the method used to connect the screw and rod: top-loading screw vs. dome screw with lateral connector.

Methods

The experiment was done on a material testing system in axial compression on three constructs consisting of two rods secured with top-loading screws and three other constructs consisting of two rods secured with dome screws and lateral connector. The maximum angle of the construct was measured during loading and after removing the load. The primary outcome measure was the mean angle in each construct at each step.

Results

The mean angle of the constructs with top-loading screws when subjected to 500 N load was significantly less than in the constructs with dome screws and lateral connector: 18.6° vs. 24.5° respectively (p<0.0003). The mean angle of the constructs with top-loading screws after removing the load was significantly less than in the constructs with dome screws and lateral connector: 25.7° vs. 32.3° respectively, (p<0.0005).

Conclusion

In vitro, top-loading screws produced significantly greater flattening than dome screws with lateral connector. These findings must be confirmed in vivo. Understanding the behavior of rods as a function of the type of screw connection can be an important factor to minimize the risk of under-correction in the sagittal plane.

Level of evidence

III.

El texto completo de este artículo está disponible en PDF.

Keywords : Spine, Pedicle screws, Rods, Sagittal alignment


Esquema


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 107 - N° 7

Artículo 102954- novembre 2021 Regresar al número
Artículo precedente Artículo precedente
  • Treatment of lumbar canal stenosis in patients with compensated sagittal balance
  • Yann Mohsinaly, Louis Boissiere, Cédric Maillot, Sébastien Pesenti, Jean-Charles Le Huec
| Artículo siguiente Artículo siguiente
  • Reliability assessment of cervical spine parameters measured on full-body radiographs in asymptomatic subjects and patients with spinal deformity
  • Michel Salameh, Aren Joe Bizdikian, Eddy Saad, Renée Maria Saliby, Rhéa Nacouzi, Nour Khalil, Ismat Ghanem, Gaby Kreichati, Ayman Assi

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.