Suscribirse

A false left ventricular non-compaction; Late discovery of a corrected transposition of the great vessels in a 63-year-old patient - 14/08/21

Doi : 10.1016/j.acvdsp.2021.06.074 
F. Saadi, Dr.  : presentator, B. Baloul, S. Hamadouche, B.V. Tung, N. Ghanem, V. Dormagen, G. Karrillon
 Hôpital Simone-Veil, 14, rue de Saint-Prix, 95600 Eaubonne 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Resumen

Abstract

We report the case of a 63-year-old patient, admitted for NSTEMI, where the first examinations in ICU are in favor of a DCM with LV non-compaction associated with AAOCA, multimodal imaging will correct the final diagnosis by objectifying the CCTGA.

History of presentation

63-year-old patient, history of murmur and cardiomegaly without real follow-up or diagnosis, dyspnea on exertion for a few months, NYHA II, who presents a typical angina associated with a significant rise in cardiac biomarkers and is admitted in ICU for NSTEMI.

Physical examination

Mitral regurgitation murmur 2/6 th, under crackles at the bases.

ECG in wide LBBB, with bradycardia, axis in VR.

NT pro BNP high.

Pulmonary x-ray shows cardiomegaly with a rebounded left edge of the heart.

Investigations

The echocardiography shows a dilated LV, very trabeculated, globular appearance, with a very wide range of non-compaction, a moderate mitral insufficiency (left valve), the operator noted in his report the impossibility to image well the aortic and pulmonary outflow tract (Fig. 1).

The patient has an angiogram which finds a weakly atheromatous network, however with AAOCA; birth of the LAD from the RCA and a very large and dominant CX giving 5 marginal branches of important caliber.

Subsequently, a CT scan and cardiac MRI were done.

First, the MRI, which finds a ventricle in a very trabecular systemic position and which clearly shows the mitro aortic rupture (major sign of TGA); as well as a wide range of late enhancement with some cryptic thrombis, the RV in the systemic position has an altered EF, LV in the upright position, with better systolic function (Fig. 2, Fig. 3).

And the CCTA that signs the NCVG with an anterior aortic birth and to the left of the PA (Fig. 4, Fig. 5).

Management

The patient was treated with altered EF treatment (recommendations differ, however, on their effectiveness in CCTGA) with establishment of an ICD-CRT in a specialized center.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2021  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 13 - N° 4

P. 316-317 - septembre 2021 Regresar al número
Artículo precedente Artículo precedente
  • Modified technique of percutaneous pulmonary valve implantation with the Sapien 3: Impact on procedure and early outcome
  • Ali Houeijeh, Clément Batteux, Emre Belli, Clément Karsenty, Jérôme Petit, Sébastien Hascoët
| Artículo siguiente Artículo siguiente
  • Preliminary experience with the new Amplatzer™ Trevisio™ delivery system in transcatheter atrial septal defect closures in children
  • Raymond N. Haddad, Diala Khraiche, Damien Bonnet, Mathilde Meot, Sophie Malekzadeh-Milani

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.