Suscribirse

Value of echocardiography to diagnose coronary arteries patterns in transposition of great arteries - 14/08/21

Doi : 10.1016/j.acvdsp.2021.06.047 
Claire Bertail-Galoin, MD , Sylvie Di Filippo, PhD
 Civil Hospices of Lyon, Louis-Pradel Hospital, Pediatric and Congenital Cardiology, University Medical Center, 69677 Bron cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Resumen

Background

Abnormal coronary pattern may complicate coronary transfer during arterial switch operation.

The objective of this study was to evaluate the accuracy of echocardiographic to assess coronary arteries anatomy in transposition of the great arteries and determine impact on outcomes.

Methods

Retrospective analysis of data in neonates with transposition of the great arteries. Preoperative echocardiographic coronary artery pattern and surgical intraoperative reports were compared. Mismatch between transthoracic echocardiography and surgical intraoperative reports, and its impact on perioperative outcome were assessed. Coronary patterns were classified in 4 groups: I=normal, II=coronary with intramural course, III=CA loop.

Results

One hundred and eight neonates who underwent arterial switch operation were included: 68 ranged in group I, 7 in group II, 32 in group III and 1 in group II+III. Intraoperative complications occurred in 10 cases. Five patients died, from coronary cause in 3 (Table 1). Survival rates were 96% at 1-month. Transthoracic echocardiography and surgical intraoperative reports differed in 17.6%. Death rates were 15.8% in case of inappropriate diagnosis and 2.2% if the diagnosis was appropriate (P=0.0108) (Fig. 1). Mortality in group II increased up to 50% in case of inappropriate diagnosis versus 0% if concordance. By multivariate analysis, an inappropriate preoperative transthoracic echocardiography diagnosis of coronary pattern was the only significant risk factor for mortality (P=0.04).

Conclusion

Echocardiography can assess coronary artery anatomy in neonates with transposition of the great arteries. Intramural coronary course is often misdiagnosed. Missed diagnosis of coronary artery anomaly preoperatively may impact on perioperative mortality.

El texto completo de este artículo está disponible en PDF.

Keywords : Transposition of the great arteries, Arterial switch operation, Echocardiography, Coronary pattern


Esquema


© 2021  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 13 - N° 4

P. 298 - septembre 2021 Regresar al número
Artículo precedente Artículo precedente
  • Congenital heart disease with neonatal revelation in Tunisia: Epidemiological, clinical and evolutionary aspects
  • Emna Cherifi, Asma Ben Zina, Yosra Sdiri, Feirouz Ayari, Myriam Cheour, Wafa Belhajammar, Nadia Benameur, Samia Kacem
| Artículo siguiente Artículo siguiente
  • Isolated fetal pericardial effusion: A case report treated by in utero pericardiocentesis
  • Marine Dorsi, Ronaldo Levy

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.