Suscribirse

New image quality and dose reduction technique for pediatric digital radiography - 26/06/21

Doi : 10.1016/j.diii.2021.01.009 
Joelle A. Feghali a, , Greg Chambers a, Julie Delépierre a, Sophie Chapeliere a, Inès Mannes a, b, Catherine Adamsbaum a, b
a AP–HP, Bicêtre Hospital, Pediatric Radiology Department, 94270 Le Kremlin-Bicêtre, France 
b Medical School, Paris-Saclay University, 94270 Le Kremlin-Bicêtre, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

A novel approach to optimise pediatric digital radiography (DR) was introduced using a simulation tool and a specific image quality grid.
S-Vue™ image denoising was applied to thorax, pelvis, abdomen and spine DR images and its effect was assessed through simulation tool and image quality grid.
S-Vue™ can yield digital radiography images of pediatric patients with high diagnostic quality at half the standard radiation dose.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The purpose of this study was to test a new post-processing and denoising engine for patient dose reduction while maintaining diagnostic image quality (IQ) in pediatric digital radiography (DR).

Materials and methods

Pediatric DR images of the thorax, pelvis, abdomen and spine obtained in 174 patients (102 males, 72 females; mean age, 2±1.8 [SD] years; age range: 6 months–9 years) were retrieved. Artificial noise was added to the images to simulate acquisitions at 50%, 32% and 12.5% of the routine dose levels. A total of 696 images corresponding to four dose levels were post-processed using S-Vue™ and further blindly scored by three pediatric radiologists using a scoring grid of 4–6 criteria specifically defined per anatomical area. The mean score was assessed for each area and weight class (5–15 and 15–30kg) and compared across the simulated low dose images. Paired Wilcoxon test was used with a threshold difference of 0.5 (half a criterion) between scores to highlight a significant reduction in image quality. Inter-rater reliability was assessed using intraclass correlation coefficient (ICC).

Results

Only the 50% reduced dose images showed non-inferiority when compared to routine images for all of areas and weight classes (P<0.01). Very good inter-rater reliability of the overall scores was observed for the pelvis in the 5–15kg weight class (ICC=0.85) for images at full dose, 50% and 32% reduced dose. For the remaining areas (thorax, abdomen and spine) and weight classes, inter-rater reliability was moderate (ICC: 0.3–0.6).

Conclusion

S-Vue™ post-processing software allows a two-fold radiation dose reduction while maintaining satisfactory IQ in pediatric DR.

El texto completo de este artículo está disponible en PDF.

Keywords : Digital radiography, Pediatrics, Dose reduction, Image processing, Image noise

Abbreviations : ALADA, ALARA, CI, CR, DR, DRL, ICC, IQ, SD


Esquema


© 2021  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 7-8

P. 463-470 - juillet 2021 Regresar al número
Artículo precedente Artículo precedente
  • MRI-based traditional radiomics and computer-vision nomogram for predicting lymphovascular space invasion in endometrial carcinoma
  • Ling Long, Jianqing Sun, Liling Jiang, Yixin Hu, Lan Li, Yong Tan, Meimei Cao, Xiaosong Lan, Jiuquan Zhang
| Artículo siguiente Artículo siguiente
  • Utility of enteric contrast material in abdominal penetrating trauma: A narrative review
  • Victoria F. Tan, Vincent M. Mellnick, Michael N. Patlas

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.