Suscribirse

Lower early revision rates after uncemented Oxford Unicompartmental Knee Arthroplasty (UKA) than cemented Oxford UKA: A meta-analysis - 27/04/21

Doi : 10.1016/j.otsr.2021.102802 
Jinhui Ma a, Yan Yan b, Weiguo Wang a, Bailiang Wang a, , Debo Yue a, Wanshou Guo a
a Department of Orthopaedic Surgery, Center for Osteonecrosis and Joint Preserving & Reconstruction, China-Japan Friendship Hospital, 2 Yinghuadong Road, Chaoyang District, Beijing 100029, China 
b Department of Orthopaedic Surgery, Peking University China–Japan Friendship School of Clinical Medicine, Beijing 100029, China 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

UKA has been proved to offer good results in treating patients with unicompartmental knee osteoarthritis (OA). However, there is still a controversy about the better fixation mode in UKA procedure between cemented and uncemented prosthesis. Therefore, this meta-analysis was conducted to compare clinical and radiological outcomes of cemented versus uncemented Oxford UKA.

Hypothesis

The study surmised that uncemented Oxford UKA was associated with shorter operation time, higher function scores, lower revision rate and less radiolucency than cemented Oxford UKA.

Methods

A meta-analysis to compare postoperative outcomes between cemented and uncemented Oxford UKA wsa conducted. The primary outcomes included Oxford knee score (OKS), revision rate, and incidence of radiolucency. The secondary outcomes included operation time, knee society score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), range of motion (ROM). PubMed, Embase, Web of Science, the Cochrane Library and China national knowledge infrastructure were searched until April, 2020 to identify studies for including. Relevant data were analyzed using RevMan v5.3.

Results

We identified nine studies involving 901 patients meeting our inclusion criteria. No significant difference of OKS was found in both groups. Compared with cemented group, uncemented Oxford UKA group was associated with lower revision rate (95% CI: 0.90 to 3.73; OR=1.83) and less radiolucent lines (95% CI: 0.79 to 9.52; OR=2.75) after following up for at least 2years. The operation time was significantly shorter by 10.12minutes (95% CI: p<0.00001) in the uncemented group when compared against the cemented group. The KSS, WOMAC, ROM were not significantly different between two groups.

Conclusions

Uncemented Oxford UKA had lower revision rate, shorter operation time and less radiolucent lines than cemented Oxford UKA did. There is still need for more long follow-up clinical trials with high evidence level to determine which method of fixation is of preferable for Oxford UKA in the future.

Level of evidence

I.

El texto completo de este artículo está disponible en PDF.

Keywords : Unicompartmental knee arthroplasty, Knee prosthesis, Cemented, Uncemented


Esquema


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 107 - N° 3

Artículo 102802- mai 2021 Regresar al número
Artículo precedente Artículo precedente
  • The ceiling effects of patient reported outcome measures for total knee arthroplasty
  • Lukas Eckhard, Selin Munir, David Wood, Simon Talbot, Roger Brighton, Bill Walter, Jonathan Baré
| Artículo siguiente Artículo siguiente
  • Oxford Knee Score and EQ-5d poorly predict patient's satisfaction following mechanically aligned total knee replacement: A cross-sectional study
  • Advaith Gummaraju, Cedric Maillot, Kwaku Baryeh, Loic Villet, Charles Rivière

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.