Suscribirse

Berlin Heart EXCOR Paediatric Ventricular Assist Device: Does Weight Matter? - 16/03/21

Doi : 10.1016/j.hlc.2020.08.012 
Virginie Fouilloux, MD, PhD a, b, 1, Fedoua El Louali, MD, PhD c, , 1 , Célia Gran, MD a, b, Roland Henaine, MD, PhD d, François Roubertie, MD, PhD e, Caroline Chenu, MD a, Marion Fiorini, MD f, Stéphane Le Bel, MD f, Philippe Mauriat, MD, PhD g, Jean Neidecker, MD h, Loïc Macé, MD, PhD a, b, Bernard Kreitmann, MD, PhD e, Caroline Ovaert, MD, PhD b, c
a Department of Paediatric and Congenital Cardiac Surgery, Timone Hospital, Marseille, France 
b Faculty of Medicine, Aix-Marseille University, Marseille, France 
c Department of Paediatric and Congenital Cardiology, Timone Hospital, Marseille, France 
d Congenital Cardiology Unit, Cardiologic Hospital Louis Pradel, Lyon, France 
e Department of Cardiovascular Surgery, Bordeaux Heart University Hospital, Bordeaux, France 
f Department of Anaesthesia and Intensive Care, Timone Children Hospital, Marseille, France 
g Department of Intensive Care Unit, Bordeaux Heart University Hospital, Bordeaux, France 
h Department of Intensive Care Unit, Cardiologic Hospital Louis Pradel, Lyon, France 

Corresponding author at: Department of Pediatric and Congenital Cardiology, Timone Hospital, 264 rue Saint-Pierre, 13 385, Marseillecedex 05, France. Tel.: +33-(0)-491386750; fax: +33-(0)-491384576Department of Pediatric and Congenital CardiologyTimone Hospital264 rue Saint-Pierre, 13 385Marseillecedex 05France

Abstract

Background

Berlin Heart EXCOR (BH) ventricular assist devices provide mechanical long-term circulatory support in children with end-stage heart failure, as a bridge to transplantation or to recovery. Most studies are from large-volume paediatric cardiac centres.

Aim

The aim of this study was to analyse the experiences of three French centres and to compare these with available published data.

Method

We performed a retrospective observational study of three paediatric cardiac intensive care units. All children supported with BH devices were included. Morbidity and mortality data were collected and risk factors analysed.

Results

Fifty-four (54) patients (54% male) were included. Survival rate was 73% while on a BH device. Median age at BH device implantation was 17 months (range 2–180 months). The predominant indication was dilated cardiomyopathy (61%). Bi-ventricular assist device was used in 25 (46%) cases. The total length of long-term circulatory support was 3,373 days, with a mean length per patient of 62.5 days (range 5–267 days). Thirty-two (32) patients were transplanted (59%) and seven (13%) were successfully weaned. Type and length of support did not influence morbidity. Main complications were renal dysfunction (57%), bleeding (41%), and infection (39%). In multivariate analysis, a weight <5 kg was significantly associated with higher mortality.

Conclusions

The weight seems to be the most important risk factor of mortality in this precarious condition.

El texto completo de este artículo está disponible en PDF.

Keywords : Ventricular failure, Assist device, Cardiomyopathy, Children


Esquema


© 2020  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 30 - N° 4

P. 585-591 - avril 2021 Regresar al número
Artículo precedente Artículo precedente
  • Percutaneous Left Ventricular Assist Device Leads to Heart Rhythm Stabilisation in Cardiogenic Shock: Results from the Dresden Impella Registry
  • Johannes Mierke, Tobias Loehn, Georg Ende, Sabrina Jahn, Silvio Quick, Uwe Speiser, Stefanie Jellinghaus, Christian Pfluecke, Axel Linke, Karim Ibrahim
| Artículo siguiente Artículo siguiente
  • Right Atrial Pressure Predicts Mortality Among LVAD Recipients: Analysis of the INTERMACS Database
  • Maya Guglin, Hesham R. Omar

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.