Suscribirse

Corrected QT Interval in Severe Aortic Stenosis: Clinical and Hemodynamic Correlates and Prognostic Impact - 04/02/21

Doi : 10.1016/j.amjmed.2020.05.035 
Maja Tschumper a, b, Lukas Weber, MD a, Hans Rickli, MD a, Sebastian Seidl, MD a, Roman Brenner, MD a, Marc Buser, MD a, Niklas F. Ehl, MD a, Franziska Jäger-Rhomberg, MD a, Peter Ammann, MD a, Micha T. Maeder, MD, PhD a,
a Cardiology Division, Kantonsspital St. Gallen, St. Gallen, Switzerland 
b Department of Internal Medicine, Spital Affoltern, Affoltern am Albis, Switzerland 

Requests for reprints should be addressed to Micha T. Maeder, MD, PhD, Cardiology Department, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007 St. Gallen, Switzerland.Cardiology DepartmentKantonsspital St. GallenRorschacherstrasse 95St. Gallen9007Switzerland

Abstract

Background

The role of the electrocardiogram for risk stratification in patients with severe aortic stenosis is not established. We assessed the hemodynamic correlates and the prognostic value of the corrected QT interval (QTc) in patients with severe aortic stenosis undergoing aortic valve replacement.

Methods

The QT interval was measured in a 12-lead electrocardiogram in 485 patients (age 74 ± 10 years, 57% male) with severe aortic stenosis (indexed aortic valve area 0.41 ± 0.13 cm2/m2, left ventricular ejection fraction 58 ± 12%) the day prior to cardiac catheterization. Prolonged QTc was defined as QTc >450 ms in men and QTc >470 ms in women. The outcome parameter was all-cause mortality.

Results

Patients with prolonged QTc (n = 100; 77 men, 23 women) had similar indexed aortic valve area but larger left ventricular and left atrial size, lower left ventricular ejection fraction, more severe mitral regurgitation, lower cardiac index, and higher mean pulmonary artery pressure, mean pulmonary artery wedge pressure, and pulmonary vascular resistance, as compared with patients with normal QTc (n = 385). After a median follow-up of 3.7 years (interquartile range, 2.6-5.2) after surgical (n = 349) or transcatheter (n = 136) aortic valve replacement, patients with prolonged QTc had higher mortality than those with normal QTc (hazard ratio 2.81 [95% confidence interval, 1.51-5.20]; P < .001). Prolonged QTc was an independent predictor of death along with more severe mitral regurgitation and higher pulmonary vascular resistance.

Conclusions

In patients with severe aortic stenosis, prolonged QTc is a marker of an advanced disease stage associated with an adverse hemodynamic profile and increased long-term mortality after aortic valve replacement.

El texto completo de este artículo está disponible en PDF.

Keywords : Aortic stenosis, Cardiac catheterization, ECG, Prognosis, QT interval


Esquema


 Funding: None.
 Conflict of Interest: None.
 Authorship: We state that all authors had access to the data and a role in writing the manuscript.


© 2020  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 134 - N° 2

P. 267-277 - février 2021 Regresar al número
Artículo precedente Artículo precedente
  • The Diagnoses and Outcomes of Emergency Patients With an Elevated D-Dimer Over the Next 90 Days
  • Christian H. Nickel, John Kellett, Tim Cooksley, Le E. Lyngholm, Simon Chang, Stephan Imfeld, Roland Bingisser, Mikkel Brabrand
| Artículo siguiente Artículo siguiente
  • Peripherally Inserted Central Catheter Thrombosis After Placement via Electrocardiography vs Traditional Methods
  • Tricia M. Kleidon, Jennifer Horowitz, Claire M. Rickard, Amanda J. Ullman, Nicole Marsh, Jessica Schults, David Ratz, Vineet Chopra

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.