Suscribirse

Variability of orthopedic physician fracture location identification: Implications for bone stimulator treatment - 12/11/20

Doi : 10.1016/j.otsr.2020.04.022 
Scott Huff a, , Joseph Henningsen a, Andrew Schneider a, Fady Hijji a, Breanna Dominguez a, Andrew Froehle a, Michael Prayson b, Jennifer Jerele b
a Department of Orthopedic Surgery, Miami Valley Hospital, Wright State University, 30, East Apple Street, Suite 2200, 45409 Dayton, OH, United States 
b Premier Orthopedics, Miami Valley Hospital, 30, East Apple Street, Suite 2200, 45409 Dayton, OH, United States 

Corresponding author at: Department of Orthopedic Surgery, Wright State University, 30, East Apple Street, Suite 2200, 45409 Dayton, OH, United States.Department of Orthopedic Surgery, Wright State University30, East Apple Street, Suite 2200Dayton, OH45409United States

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Aseptic non-union is a significant complication in approximately 5% of long-bone fractures. External bone stimulation treatment is often attempted before more invasive surgical interventions. Bone stimulators can have favorable results, but have a limited 1.7cm therapeutic radius. This study evaluated the accuracy by which clinicians locate a fracture on a cadaveric model. This has implications for the clinician's ability to accurately counsel patients on daily bone stimulator placement. Additionally, physicians (orthopedic attending surgeons and residents) were compared with pre-clinical (M1 and M2) medical students to evaluate if higher levels of training improved accuracy.

Hypothesis

Orthopedic physicians and pre-clinical medical students will localize a radiographic fracture within 1.7cm less than 100% of the time, which represents the ideal consistency for patient care. Furthermore, orthopedic physicians will achieve a higher percentage accuracy than pre-clinical medical students.

Materials and methods

The sample included 20 orthopedic physicians and 16 pre-clinical medical students. Upper (radius) and lower (tibia) extremity cadaver models were prepared by inducing a single, transverse diaphyseal fracture. Plain reference radiographs of each model were obtained. Participants placed a radiopaque marker onto each model at the perceived fracture location, and radiographs were taken to document placement. Perpendicular marker-to-fracture distance was measured to the nearest mm along each bone's long axis using the PACS system.

Results

Placement within the therapeutic radius was achieved by 70–80% of physicians, and 69–75% of medical students. In the remaining participants, improper placement distances were lower among physicians than among medical students (radius: 2.1±0.5 vs. 3.6±0.9cm, p=0.02; tibia: 2.6±0.5 vs 3.5±0.5cm, p=0.89).

Discussion

In two cadaveric fracture models, up to 30% of orthopedic surgeons perceived a fracture location to be outside a bone stimulator's 1.7cm therapeutic radius. This finding suggests that physicians and their patients may benefit from additional methods for specifying the location of a non-union before commencing daily bone stimulator treatment.

Level of evidence

Level IV, prospective cohort study-evidence from a well-designed prospective cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Radiographic identification, Fracture localization, Bone stimulator, Non-union


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 7

P. 1383-1390 - novembre 2020 Regresar al número
Artículo precedente Artículo precedente
  • Risk factors associated with unsatisfactory hip function in children with late-diagnosed developmental dislocation of the hip treated by open reduction
  • YiQiang Li, Wei Hu, FuXing Xun, XueMei Lin, JingChun Li, Zhe Yuan, YanHan Liu, Federico Canavese, HongWen Xu
| Artículo siguiente Artículo siguiente
  • Intramedullary nailing versus a locking compression plate for humeral shaft fracture (AO/OTA 12-A and B): A retrospective study
  • Ruipeng Zhang, Yingchao Yin, Shilun Li, Zhiyong Hou, Lin Jin, Yingze Zhang

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.