Suscribirse

Mechanical behavior of screw versus Endobutton for coracoid bone-block fixation - 23/09/20

Doi : 10.1016/j.otsr.2020.03.035 
Vadim Azoulay a, b, Jérôme Briot b, Pierre Mansat a, b, Pascal Swider a, b, Nicolas Bonnevialle a, , b
a Service d’orthopédie, CHU de Toulouse, place Baylac, 31059 Toulouse cedex 09, France 
b Laboratoire de biomécanique, institut de mécanique des fluides de Toulouse UMR CNRS 5502, Toulouse, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Arthroscopic coracoid bone-block fixation by Endobutton was developed to avoid the complications associated with screwing. However, few studies have assessed the mechanical characteristics of the two. The aim of the present study was to assess and compare fixation rigidity by screw versus Endobutton. The study hypothesis was that rigidity is lower with Endobutton than with screws.

Material and method

3D print-outs of a glenoid and a coracoid process were obtained from CT scans of a patient showing anterior shoulder instability with significant bone defect. Four types of coracoid fixation were implemented: 1 or 2 4.5mm malleolar screws, and 1 or 2 Endobuttons. Three specimens per assembly were placed on a specific test bench. Lateromedial bone-block compression was exerted at 0.1mm/sec at 3 points: superior, central, inferior. The resultant force and bone-block displacement were recorded.

Results

Mean fixation rigidity with 1 screw, 2 screws, 1 Endobutton and 2 Endobuttons was respectively 158N/mm (range, 133–179), 249N/mm (241–259), 10N/mm (5–13) and 14N/mm (13–15), with significant difference between the screw and Endobutton groups (p<0.001). Displacement was greater with 1 than 2 Endobuttons under superior or inferior force, while the difference was non-significant under central force (7.45 vs 6.93mm; p=0.53)

Conclusions

Screw fixation showed greater rigidity, while the Endobutton assembly showed less tension, leading to greater bone-block mobilization. The interest of using two Endobuttons is to reduce displacement under polar pressure. the present biomechanical study confirmed the mechanical vulnerability of bone-blocks fixed by endobutton until consolidation is achieved.

Level of evidence

Biomechanical study.

El texto completo de este artículo está disponible en PDF.

Keywords : Latarjet, Double-button, Endobutton, Bone block, Instability, Shoulder, Biomechanics


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 6

P. 1089-1093 - octobre 2020 Regresar al número
Artículo precedente Artículo precedente
  • Basic morphological characteristics of coracoid grafts obtained by open and arthroscopic Latarjet techniques: A comparative study
  • Alvaro Minuesa-Asensio, Francisco García-Esteo, José Ramón Mérida-Velasco, Carmen Barrio-Asensio, Crótida de la Cuadra-Blanco, Jorge Murillo-González
| Artículo siguiente Artículo siguiente
  • C5/C6 brachial plexus palsy reconstruction using nerve surgery: long-term functional outcomes
  • Laure Pages, Malo Le Hanneur, Adeline Cambon-Binder, Zoubir Belkheyar

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.