Suscribirse

A systematic review of automated feeder detection software for locoregional treatment of hepatic tumors - 29/07/20

Doi : 10.1016/j.diii.2020.01.011 
Z. Cui a, P.A. Shukla b, P. Habibollahi c, H.S. Park c, A. Fischman d, M.K. Kolber c,
a UT Southwestern Medical Center, 5323 Harry Hines Blvd., 75390-9003 Dallas, TX, USA 
b Division of Interventional Radiology, Department of Radiology, Rutgers New Jersey Medical School, MSB F-506, 07103 Newark, NJ, USA 
c Division of Vascular and Interventional Radiology, Department of Radiology, University of Texas Southwestern Medical Center, 75390 Dallas, TX, USA 
d Division of Vascular and Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, 10029 New York, NY, USA 

Corresponding author at: Division of Vascular and Interventional Radiology, Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, 75390 Dallas, TX, USA.Division of Vascular and Interventional Radiology, Department of Radiology, University of Texas Southwestern Medical Center5323 Harry Hines BoulevardDallas, TX75390USA

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The purpose of this study was to perform a systematic review of current literature describing the efficacy and technical outcomes of transarterial liver therapies using automated feeder detection (AFD) software.

Materials and methods

This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. A structured search was performed in the PubMed, SCOPUS, and Embase databases of patients undergoing locoregional therapy of liver tumors utilizing AFD software. Demographic data, procedure data (including radiometrics) and tumor response rate were recorded. Where available, performance of AFD was compared to conventional digital subtraction angiography (DSA) and cone-beam CT (CBCT) without AFD.

Results

A total of 14 full-text manuscripts met inclusion criteria, comprising 1042 tumors in 604 patients (305 men, 156 women; mean age, 68.6±6.0 [SD] years), including 537 patients with hepatocellular carcinoma, 8 with metastases from neuroendocrine tumors, and 59 patients without reported etiology. Reported sensitivity of AFD ranged between 86% and 98.5%, compared to DSA alone (38% – 64%) or DSA in combination with CBCT (69% – 81%). Three studies reported tumor response by modified response evaluation criteria in solid tumors (mRECIST) guidelines, with complete response in the range of 60% – 69%.

Conclusion

AFD is a promising new technology for the identification of intrahepatic and extrahepatic tumor-feeding arteries and should be considered a useful adjunct to conventional DSA and CBCT in the treatment of liver tumors.

El texto completo de este artículo está disponible en PDF.

Keywords : Cone-beam computed tomography, Liver neoplasm, Automated feeder detection, Angiography, Digital subtraction


Esquema


© 2020  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 7-8

P. 439-449 - juillet 2020 Regresar al número
Artículo precedente Artículo precedente
  • Chest CT in COVID-19 pneumonia: A review of current knowledge
  • C. Jalaber, T. Lapotre, T. Morcet-Delattre, F. Ribet, S. Jouneau, M. Lederlin
| Artículo siguiente Artículo siguiente
  • Glioma-grade diagnosis using in-phase and out-of-phase T1-weighted magnetic resonance imaging: A prospective study
  • M. De Pardieu, S. Boucebci, G. Herpe, C. Fauche, S. Velasco, P. Ingrand, J.-P. Tasu

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.