Suscribirse

Eliminating projection error of measuring Pauwels’ angle in the femur neck fractures by CT plane manipulation - 08/06/20

Doi : 10.1016/j.otsr.2019.09.029 
Gyu Min Kong a, Jae-Man Kwak b, Gu-Hee Jung c, d,
a Department of Orthopaedic surgery, Inje university, Busan Paik hospital, 75, Bokji-ro, Busanjin-Gu, Busan, Republic of Korea 
b Department of Orthopedics, Biomechanics Laboratory, Mayo Clinic, Rochester, MN, USA 
c Department of Orthopaedic surgery, Gyeongsang national university, college of medicine, Gyeongsang national university changwon hospital, 11, Samjeongja-ro, Seongsan-gu, Changwon-si 51472, Republic of Korea 
d Medical ICT Convergence research center, institute of Health Sciences, college of Medicine, Gyeongsang National University, 816 Beongil 15, Jinju-si 52727, Republic of Korea 

Corresponding author at: Department of Orthopaedic surgery, Gyeongsang national university, college of medicine, Gyeongsang national university changwon hospital, 11, Samjeongja-ro, Seongsan-gu, Changwon-si 51472, Republic of Korea.Department of Orthopaedic surgery, Gyeongsang national university, college of medicine, Gyeongsang national university changwon hospital11, Samjeongja-ro, Seongsan-guChangwon-si 51472Republic of Korea

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Objectives

The aim for the present study was to determine whether projection error of measuring Pauwels’ angle in young femur neck fracture could be eliminated by CT plane manipulation.

Methods

Clinical data of displaced femur neck fractures in young adults aged 20 to 64years old (13 females and 17 males) were retrospectively analyzed. Their average age was 47.9years (range: 22–64years; SD: 11.3). Using modified measurement method for Pauwels’ angle using central line of the shaft as a guideline, the angle of a conventional coronal CT image was measured. CT images were imported into Mimics® software. The scanning plane was then reformatted parallel to the neck axis to eliminate projection error of injured limb. Measured angles were classified into three types (I<30°; II, 30–50°; and III>50°) and differences were analyzed.

Results

Average Pauwels’ angle was 52.9° (range: 28.6–68.3°; SD: 9.9; type II, 17 cases; type III, 13 cases) for conventional CT images and 68.7° (range: 29.8–91.2°; SD: 13.4; type II, 1 cases; type III, 29 cases) for reformatted CT images. Difference between these two measurements on average was 15.7° (range: 1.2–34.9°; SD: 7.3).

Conclusions

Reformatting CT scanning plane by manipulating the proximal fragment to be parallel with the neck axis of the distal neck-shaft fragment is a convenient and reliable technique for eliminating the projection error of measuring Pauwels’ angle in the femur neck fractures.

Level of evidence

IV, cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Femur neck fracture, Young adult, Pauwels angle, Projection error


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 4

P. 607-611 - juin 2020 Regresar al número
Artículo precedente Artículo precedente
  • Poor results of functional treatment of Garden-1 femoral neck fracture in dependent patients
  • Roger Erivan, Marion Soleihavoup, Guillaume Villatte, Daniel Perez Prieto, Stéphane Descamps, Stéphane Boisgard
| Artículo siguiente Artículo siguiente
  • Prospective assessment of trochanteric fracture managed by intramedullary nailing with controlled and limited blade back-out
  • Manuela Barla, François Egrise, Bogdan Zaharia, Camille Bauer, Jauffrey Parot, Didier Mainard

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.