Abstract

Introduction

Tension band wiring is considered the standard treatment for transverse olecranon fractures. Its main complications are pin migration and discomfort caused by the hardware. We have designed and used “expulsion-proof” pins (EPP) that are shaped to prevent migration and reduce discomfort. This study compared the complication rate between our device and Kirschner pins (controls).

Hypothesis

We hypothesised that EPP would have lower migration rates and fewer complications than standard Kirschner pins.

Materials and methods

This retrospective, single-center, multi-operator, observational, study examined data from January 1996 to December 2014. The primary outcome was the occurrence of pin migration. Secondary outcomes were the occurrence of one or more additional complications and the hardware removal rate.

Results

The study enrolled 101 patients: 53 (52.4%) with expulsion-proof pins and 48 (47.6%) controls. The mean follow-up was 240.6days in the EPP group and 268.9days in the control group. No cases of migration (0%) were found in the EPP group versus 21 (43.7%) cases in the controls (p<0.05). One or more complications occurred in 18 (33.9%) patients in the EPP group versus 46 (95.8%) controls (p<0.05). There was material discomfort in 13 (24.5%) cases and 1 (1.9%) case of secondary displacement in the EPP group, compared with 38 (79.2%) and 7 (14.6%) cases, respectively, in the controls (p<0.05). The rate of delayed consolidation was statistically identical in the two groups (p=0.103). The hardware was removed in 13 (24.5%) cases in the EPP group compared with 36 (75%) controls (p<0.05).

Conclusion

EPPs are useful for management of olecranon fractures treated via TBW: the pins do not migrate and can reduce complications, discomfort, secondary displacement, and the hardware removal rate.

Level of evidence

Level III, retrospective comparative study.

El texto completo de este artículo está disponible en PDF.

Keywords : Olecranon fractures, Pin migration, Tension band wiring


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 8

P. 1593-1599 - décembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Factors affecting outcome of partial radial head fractures: A Retrospective Cohort Study
  • Anne Couture, Jonah Hébert-Davies, Julien Chapleau, G. Yves Laflamme, Emilie Sandman, Dominique M. Rouleau
| Artículo siguiente Artículo siguiente
  • Clinical evaluation of double-plate osteosynthesis for olecranon fractures: A retrospective case-control study
  • Alexander Ellwein, Konstantinos Argiropoulos, Rony-Orijit DeyHazra, Marc-Frederic Pastor, Tomas Smith, Helmut Lill

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.