Abstract

Background

The direct minimally invasive anterior approach (DMIAA) in total hip arthroplasty (THA) is widely accepted. In our department the DMIAA according to Rachbauer together with the Trident cup and Accolade stem was introduced in 2004. The purpose of the study was to demonstrate the five-year results and to analyze the learning curve of a new introduced approach.

Patients and methods

Between July 2004 and May 2006, a consecutive series of 151 THA in 147 patients was retrospectively analyzed. All patients were planned to received a THA with the Accolade/Trident implant system using the DMIAA without traction table. Clinical and radiographic data, complications and survivorship were documented with a follow-up of at least 5 years.

Results

Regarding cup implantation, there were 11 (7.3%) failed intentions to treat due to missing pressfit (8 cases) and acetabular floor perforation (3 cases). No failed intentions to treat occurred during stem implantation. Total implant survival after 5 years follow-up after exclusion of 11 cases with failed intention to treat (N=140) was 96.9% (SD 1.4; CI 94.3–99.6). After exclusion of the failed intentions to treat (N=140, N=4 in the first 20 cases), there was significant (p<0.001) difference between the first 16 implants with a 5 year-survival of 83.2% (SD 8.6; CI 66.4–100) and 95.7% (SD 0.9; CI 93.9–97.5) for the following 124 implants. Radiolucent lines were observed in Gruen zone 1 in 3.3% and in Gruen zone 1 and 2 in 1.1%.

Discussion

THA with Accolade/Trident using the DMIAA without traction table according to Rachbauer temporary exposed patients to a higher risk of implant revisions, which was normalized after the first 20 cases. Results of the learning curve are comparable to other techniques using an orthopaedic traction table. After the typical learning curve, the rate of 5 years implant failure is in accordance with the registry data for non-cemented implants. The Accolade stem showed minimal radiographic signs of radiolucency.

Level of evidence

IV, retrospective, consecutive case series.

El texto completo de este artículo está disponible en PDF.

Keywords : Primary THA, Anterior approach, Supine position


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 5

P. 931-936 - septembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • ALDI (Anterior Lateral Decubitus Intermuscular) approach to the hip: Comprehensive description of the surgical technique with operative video
  • Serafino Carta, Mattia Fortina
| Artículo siguiente Artículo siguiente
  • Ten-year outcomes of cementless anatomical femoral implants after 3D computed tomography planning. Follow-up note
  • Olivier Tostain, Emmanuel Debuyzer, Kevin Benad, Sophie Putman, Adeline Pierache, Julien Girard, Gilles Pasquier

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.