Suscribirse

What factors predict ceramic liner malseating after ceramic-on-ceramic total hip arthroplasty? - 21/04/19

Doi : 10.1016/j.otsr.2019.01.009 
Yoshitoshi Higuchi , Taisuke Seki, Yasuhiko Takegami, Yusuke Osawa, Taiki Kusano, Naoki Ishiguro
 Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Japan 466-8550 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

There is a lack of evidence about the risk factors associated with the malseating of the acetabular liner after ceramic-on-ceramic (CoC) total hip arthroplasty (THA). Therefore, we performed a complementary retrospective case-control study to determine the factors predicting the malseating of the acetabular liner after CoC THA and to evaluate the relationship between malseating and (1) osteoarthritis, (2) particularly in terms of the new radiographic parameter “bone sclerotic length” of the acetabular bone.

Hypothesis

Osteoarthritis, particularly bone sclerotic length, was an independent risk factor for malseating of ceramic liners.

Patients and methods

In total, 219 CoC THAs (174 women and 45 men) were evaluated to determine the risk factors influencing the malseating of the acetabular ceramic liner. An average patient age at the time of surgery was 55.9±9.5 years (range, 23 to 75 years). Data on patient background and preoperative radiographs, such as Tönnis grades; Crowe classification; and indices of acetabular osteoarthritis change; including bone cyst, osteophyte and bone sclerosis, were assessed. The bone sclerotic length in patients with osteoarthritis was measured as the slant distance between the bilateral edges of the sclerosis lesion of the acetabulum on the anteroposterior view.

Results

Preoperative less hip flexion (hazard ratio [HR]: 0.98; 95% CI: 0.97–0.99), osteoarthritis (HR: 3.15; 95% CI: 1.02–9.70) and the bone sclerotic length (HR: 1.83; 95% CI: 1.35–2.48) were independent risk factors determining the malseating of ceramic liners. Receiver operating characteristic curve analysis showed that a bone sclerotic length of 24.6mm was defined as the cut-off point for the malseating of the ceramic liner.

Discussion

Age, preoperative less flextion, osteoarthritis, and the bone sclerotic were independent risk factors determining malseating of ceramic liners. The acetabular shell can also deform upon insertion of the cup with sclerotic bone of the acetabulum and prevent correct seating of liners. Therefore, these factors must be taken into consideration when seating the ceramic liner.

Level of evidence

Case control study III, case control retrospective design.

El texto completo de este artículo está disponible en PDF.

Keywords : Ceramic on ceramic bearings, Total hip arthroplasty, Liner malseating, Risk factor, Ceramic liner with a metal-back titanium sleeve


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 3

P. 453-459 - mai 2019 Regresar al número
Artículo precedente Artículo precedente
  • Does the direct anterior approach allow earlier recovery of walking following total hip arthroplasty? A randomized prospective trial using accelerometry
  • Gautier Bon, Elias Ben Kacem, Pierre Marie Lepretre, Thierry Weissland, Patrice Mertl, Massinissa Dehl, Antoine Gabrion
| Artículo siguiente Artículo siguiente
  • Dual mobility device reduces the risk of prosthetic hip instability for patients with degenerated spine: A case-control study
  • Louis Dagneaux, Stanislas Marouby, Cedric Maillot, François Canovas, Charles Rivière

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.