Suscribirse

Tests for predicting reimplantation success of two-stage revision for periprosthetic joint infection: A systematic review and meta-analysis - 29/10/18

Doi : 10.1016/j.otsr.2018.03.017 
Tao Bian, Hongyi Shao, Yixin Zhou , Yong Huang, Yang Song
 Department of Orthopedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No. 31 Xinjiekou East Street, 100035 Beijing, Xicheng District, China 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Several tests are used before reimplantation to detect persistent infection in patients with periprosthetic joint infection (PJI) undergoing two-stage revision. However, there is no consensus as to the optimal tests for excluding persistent infection or predicting successful reimplantation by stage. We aimed to determine the accuracy of different tests used to detect persistent infection after the first stage, and/or predicting failure following reimplantation in patients with PJI.

Methods

We conducted a systematic review and meta-analysis of PubMed, Embase and the Cochrane Library databases. Two reviewers independently conducted quality assessments and data extractions to estimate pooled sensitivity and specificity, diagnostic odds ratio and area under the receiver operating characteristic curves (AUSROC) for each test.

Results

We included 24 studies published between May 1999 and September 2017. Synovial fluid polymorphonuclear neutrophils (PMN)% had the highest sensitivity of 0.70, followed by serum erythrocyte sedimentation rate (0.57) and spacer sonication fluid culture (0.53). Synovial fluid culture had the highest specificity of 0.97, followed by frozen section (0.93) and the Musculoskeletal Infection Society criteria (0.92). Spacer sonication fluid culture was the most accurate test with an AUSROC of 0.8089, followed by synovial fluid culture (0.7749) and frozen section (0.7819).

Discussion

Spacer sonication fluid culture had a relatively high diagnostic accuracy. We emphasize that no test can be used alone to exclude persistent infection beyond the first stage and/or predict failed reimplantation beyond the second stage.

Level of evidence

II, systematic review and meta-analysis of level 2 to level 4 studies with inconsistent results.

El texto completo de este artículo está disponible en PDF.

Keywords : Diagnostic tests, Infection, Sonication, Two stage, Spacer, Meta-analysis


Esquema


© 2018  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 7

P. 1115-1123 - novembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Comparison of volar versus dorsal screw fixation for scaphoid waist fractures: A finite element analysis
  • Baver Acar, Ozkan Kose, Yusuf Alper Kati, Omer Faruk Egerci, Adil Turan, Halil Yalc?n Yuksel
| Artículo siguiente Artículo siguiente
  • Update on the supply and use of allografts in locomotor system pathologies in France
  • Roger Erivan, Guillaume Villatte, Matthieu Ollivier, Stéphane Descamps, Stéphane Boisgard

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.