Suscribirse

Alignment options for total knee arthroplasty: A systematic review - 07/11/17

Doi : 10.1016/j.otsr.2017.07.010 
C. Rivière a, , F. Iranpour a, E. Auvinet a, S. Howell b, P.-A. Vendittoli c, J. Cobb a, S. Parratte d
a Laboratory Block, Charing Cross Campus, Fulham Palace Rd, W6 8RP London United Kingdom 
b Division of Orthopedic Surgery, Methodist Hospital, 7500 Hospital Dr, 95823 Sacramento, CA, USA 
c Service de chirurgie orthopédique, hôpital Maisonneuve-Rosemont, 5415 Assumption Blvd, H1T 2M4 Montréal, Québec, Canada 
d Service de chirurgie orthopédique, hôpital Sainte-Marguerite, université Aix-Marseille, 20, avenue Viton, 13009 Marseille, France 

Corresponding author. The MSK Lab, Charing Cross Campus, Laboratory Block, London W6 8RP Imperial College London, United Kingdom.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

In spite of improvements in implant designs and surgical precision, functional outcomes of mechanically aligned total knee arthroplasty (MA TKA) have plateaued. This suggests probable technical intrinsic limitations that few alternate more anatomical recently promoted surgical techniques are trying to solve. This review aims at (1) classifying the different options to frontally align TKA implants, (2) at comparing their safety and efficacy with the one from MA TKAs, therefore answering the following questions: does alternative techniques to position TKA improve functional outcomes of TKA (question 1)? Is there any pathoanatomy not suitable for kinematic implantation of a TKA (question 2)? A systematic review of the existing literature utilizing PubMed and Google Scholar search engines was performed in February 2017. Only studies published in peer-reviewed journals over the last ten years in either English or French were reviewed. We identified 569 reports, of which 13 met our eligibility criteria. Four alternative techniques to position a TKA are challenging the traditional MA technique: anatomic (AA), adjusted mechanical (aMA), kinematic (KA), and restricted kinematic (rKA) alignment techniques. Regarding osteoarthritic patients with slight to mid constitutional knee frontal deformity, the KA technique enables a faster recovery and generally generates higher functional TKA outcomes than the MA technique. Kinematic alignment for TKA is a new attractive technique for TKA at early to mid-term, but need longer follow-up in order to assess its true value. It is probable that some forms of pathoanatomy might affect longer-term clinical outcomes of KA TKA and make the rKA technique or additional surgical corrections (realignment osteotomy, retinacular ligament reconstruction etc.) relevant for this sub-group of patients. Longer follow-up is needed to define the best indication of each alternative surgical technique for TKA. Level I for question 1 (systematic review of Level I studies), level 4 for question 2.

El texto completo de este artículo está disponible en PDF.

Keywords : TKA, Alignment, Kinematic alignment, Anatomic alignment, Adjusted technique, Restricted technique


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 7

P. 1047-1056 - novembre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Bilateral simultaneous unicompartmental knee arthroplasty versus unilateral total knee arthroplasty: A comparison of the amount of blood loss and transfusion, perioperative complications, hospital stay, and functional recovery
  • J.H. Ahn, D.M. Kang, K.J. Choi
| Artículo siguiente Artículo siguiente
  • Mechanical alignment technique for TKA: Are there intrinsic technical limitations?
  • C. Rivière, F. Iranpour, E. Auvinet, A. Aframian, K. Asare, S. Harris, J. Cobb, S. Parratte

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.