Suscribirse

Arthroscopic congruent-arc shoulder bone-block for severe glenoid bone defect: Preliminary report - 21/04/17

Doi : 10.1016/j.otsr.2016.11.023 
J. Kany a, , B. Codanda b, P. Croutzet a, R. Guinand a
a Clinique de l’Union, Shoulder, Boulevard de Ratalens, 31240 Saint-Jean, France 
b Sakra World Hospital, Bangalore, India 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Glenoid bone defect remains a surgical challenge in managing anterior shoulder instability. The technique first described by Latarjet has become the gold standard, but may fail to restore fully normal anatomy in case of severe “inverted-pear” glenoid bone defect. Likewise, the naturally “banana-shaped” coracoid process fails to match this flat shoulder. The congruent-arc modified Latarjet technique, which consists in pivoting the coracoid process through 90°, optimizes the contact surface, adapting to the glenoid curvature radius and increasing the articular surface of the graft.

Hypothesis

The present study hypothesis was that the congruent-arc bone-block technique could be performed entirely under arthroscopy. The main study objective was to assess the postoperative increase in glenoid surface area. The secondary objective was to assess whether the technique provided anatomic glenoid reconstruction.

Materials and methods

Five patients with inverted-pear glenoid were recruited in a preliminary prospective study. Immediate postoperative coracoid process length, width and thickness were measured on 2D CT scan and bone-block flushness was assessed using a straight-line and a circle. Glenoid surface area and coracoid graft area were also measured.

Results

Mean coracoid process length was 2.62cm (range, 2.17–3.05cm), width 1.52cm (range, 1.28–1.75cm) and thickness 1.16cm (range, 0.9–1.3cm). Mean preoperative glenoid area was 5.62 cm2 (range, 4.76–6.31cm2) and the articular area of the coracoid process was 2.78 cm2 (range, 2.43–3.27cm2). The coracoid graft thus increased glenoid area by a mean 49.2% (range, 41–53%). Axial CT slices systematically showed good bone-block positioning.

Discussion and conclusion

The congruent-arc technique can be performed entirely under arthroscopy, and provides anatomic glenoid reconstruction. It offers an option in case of severe inverted-pear glenoid bone defect.

Type of study

Prospective.

Level of evidence

III, case-control.

El texto completo de este artículo está disponible en PDF.

Keywords : Latarjet, Arthroscopy, Congruent-arc, Inverted-pear glenoid, Shoulder instability


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 3

P. 441-446 - mai 2017 Regresar al número
Artículo precedente Artículo precedente
  • Surgical repair of massive rotator cuff tendon tears: Autologous quadriceps tendon graft versus arthroscopic repair
  • C. Tempelaere, P. Desmoineaux, F. Lespagnol, J. Pierrart, P. Beaufils, N. Pujol
| Artículo siguiente Artículo siguiente
  • Lasso plate – An original implant for fixation of type I and II Regan-Morrey coronoid fractures
  • P. Wang, Y. Zhuang, Z. Li, W. Wei, Y. Fu, X. Wei, K. Zhang

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.