Suscribirse

Acetate templating on calibrated standing digital radiograph improves accuracy of preoperative templating for total hip arthroplasty - 21/04/17

Doi : 10.1016/j.otsr.2016.12.022 
Q. Wang a, 1, J. Xiao b, 1, L. Zhu c, X. Zhao a, Z. Liu a, J. Wang a, Y. Qin a,
a Department of Orthopaedic Surgery, 2nd Hospital of Jilin University, 218#, Zi Qiang Street, Changchun, Jilin, 130041, China 
b Department of Orthopaedic Surgery, China-Japan Union Hospital of Jilin University, 126#, Xian Tai Street, Changchun, Jilin, 130033, China 
c Changchun University of Chinese Medicine, 1035#, Bo Shuo Street, Changchun, Jilin, 130000, China 

Corresponding author. Department of Orthopaedic Surgery, 2nd Hospital of Jilin University, No. 18, Ziqiang street, Nanguan District, Changchun 130041, China.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

The accuracy of preoperative templating with respect to leg length, femoral offset, and the size of femoral and acetabular components is essential to the success of total hip arthroplasty (THA). Traditionally, templating has been performed using printed film with acetate templates. However, preoperative templating designed by different prosthetic manufacturers cannot be used directly on the film due to varying acetate template amplification ratios. Computer-based templating needs specialized digital templating software, which has cost implications. To address these shortcomings, we bring forward several questions: (1) the accuracy of traditional manual templating combined with the calibrated digital radiograph for preoperative templating, (2) the inter- and intraobserver reliability of this method.

Hypothesis

Using calibrated digital radiograph with traditional manual templating improves the accuracy and reproducibility of preoperative templating for THA.

Patients and methods

We designed a stepwise method that combines the traditional manual templating with standing digital radiograph calibrated by a scaling ball. Two separate observers (XJL, QYG) analyzed data of 82 patients (109 THAs) who had undergone THA with preoperative templating using the calibrated digital templating. The intra- and interobserver reliability was assessed by intraclass correlation coefficient.

Results

The size of the acetate template acetabular based on our method was identical to the actual implanted acetabular size in 55.0% (XJL 110/218 [50.5%]; QYG 130/218 [59.6%]) of the cases indicating moderate accuracy. The intraclass correlation coefficient (ICC) for acetabular templating indicated almost perfect interobserver (ICC=0.918 [95% CI, 0.893–0.937]) and intraobserver agreement (ICC=0.932 [95% CI, 0.912–0.947]). While the exact implanted femoral size was predicted in 55.3% (XJL 122/218 [56.0%]; QYG 119/218 [54.6%]) of the cases. The ICC for femoral component templating indicated almost perfect interobserver (ICC=0.944 [95% CI, 0.927–0.957]) and intraobserver agreement (ICC=0.909 [95% CI, 0.883–0.930]).

Discussion

This new stepwise method may prove to be a more reliable preoperative design choice to accurately calibrate magnification with radiograph, and could solve the incompatibility of the preoperative template designed by different prosthetic companies for direct use with the x-ray film. The method described is practical, convenient, cost-effective and does not require specialized equipment or software, thus making it particularly suitable for use in underdeveloped settings.

Level of evidence

Level IV, case series without controls.

El texto completo de este artículo está disponible en PDF.

Keywords : Calibration, Standing digital radiograph, Templating, THA


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 3

P. 341-347 - mai 2017 Regresar al número
Artículo precedente Artículo precedente
  • Epidemiology and treatment of acetabular fractures in a level-1 trauma centre: Retrospective study of 414 patients over 10 years
  • M. Boudissa, F. Francony, G. Kerschbaumer, S. Ruatti, M. Milaire, P. Merloz, J. Tonetti
| Artículo siguiente Artículo siguiente
  • Is there a role for femoral offset restoration during total hip arthroplasty? A systematic review
  • M. De Fine, M. Romagnoli, A. Toscano, A. Bondi, M. Nanni, S. Zaffagnini

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.