Suscribirse

Endoscopic slip-knot clip suturing method: prospective pilot study (with video) - 20/04/17

Doi : 10.1016/j.gie.2016.07.047 
Toshihiro Nishizawa, MD, PhD 1, 2, , Yasutoshi Ochiai, MD, PhD 1, Toshio Uraoka, MD, PhD 1, 3, Teppei Akimoto, MD 1, Yutaka Mitsunaga, MD 1, Osamu Goto, MD, PhD 1, Ai Fujimoto, MD, PhD 1, Tadateru Maehata, MD, PhD 1, Takanori Kanai, MD, PhD 2, Naohisa Yahagi, MD, PhD 1
1 Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Tokyo, Japan 
2 Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Tokyo, Japan 
3 Division of Gastroenterology, National Hospital Organization Tokyo Medical Center, Tokyo, Japan 

Reprint requests: Toshihiro Nishizawa, MD, PhD, Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.Division of Gastroenterology and HepatologyDepartment of Internal MedicineKeio University School of Medicine35 ShinanomachiShinjuku-kuTokyo 160-8582Japan

Abstract

Background and Aims

We developed a suturing method with a slip-knot string and clips for a single-channel endoscope. The feasibility of the slip-knot clip suturing method was evaluated in this clinical pilot study.

Methods

Ten patients underwent endoscopic submucosal dissection for colorectal and duodenal tumors 5 cm or less. A slip-knot loop can be tightened when tension is applied to the free end of the string. A clip and string can be passed through an instrument channel (3.2 mm) of a single-channel endoscope. The slip-knot loop is anchored onto the mucosal defect’s proximal margin with the clip. Additional clips anchoring the slip-knot loop are placed at the opposite side of the margin. The slip-knot loop is tightened by pulling the string. Additional clips are placed to achieve complete closure.

Results

The mean size of resected specimen was 34.4 ± 10.0 mm. The success rate of the slip-knot clip suturing method was 90% (9/10). In the first patient, the string was cut because of friction, and the patient dropped out of the study. After the failure of the first patient, we used wet string to reduce friction, and slip-knot string worked effectively. The mean procedure time was 18.2 ± 3.3 minutes.

Conclusion

The slip-knot clip suturing method could close large mucosal defects completely using a single-channel endoscope. (Clinical trial registration number: UMIN000017583.)

El texto completo de este artículo está disponible en PDF.

Abbreviation : ESD


Esquema


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Nishizawa at nisizawa@kf7.so-net.ne.jp.


© 2017  American Society for Gastrointestinal Endoscopy. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 85 - N° 2

P. 433-437 - février 2017 Regresar al número
Artículo precedente Artículo precedente
  • Biliary bypass redux: lessons for the therapeutic endoscopist from the archives of surgery
  • Eduardo Rodrigues-Pinto, Ian S. Grimm, Todd H. Baron
| Artículo siguiente Artículo siguiente
  • Maneuverability and safety of a magnetic-controlled capsule endoscopy system to examine the human colon under real-time monitoring by colonoscopy: a pilot study (with video)
  • Hongxiang Gu, Huiling Zheng, Xiaobing Cui, Ying Huang, Bo Jiang

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.