Suscribirse

Efficacy and safety of carbon dioxide insufflation versus air insufflation for endoscopic retrograde cholangiopancreatography: A meta-analysis update - 08/03/17

Doi : 10.1016/j.clinre.2016.10.001 
Wen You Zhang a, b, Xue Pei Jiang a, b, Lei Miao a, b, Fei Chi Chen a, b, Zhi Ming Huang a, , Xie Lin Huang c
a Departments of Gastroenterology and Hepatology, First Affiliated Hospital of Wenzhou Medical University, Shangcai Street, Nanbaixiang Town, Ouhai District, 325000 Wenzhou, China 
b School of First Clinical Medical, Wenzhou Medical University, Chashan Advanced Education Park, 325000 Wenzhou, China 
c School Renji Clinical Medical, Wenzhou Medical University, Advanced Education Park, Wenzhou, China 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 13
Iconografías 6
Vídeos 0
Otros 0

Summary

Background and objective

Endoscopic retrograde cholangiopancreatography (ERCP) is essential for visualising the biliary tree and pancreatic ducts, and carbon dioxide (CO2) insufflation during ERCP is considered an alternative technique to air insufflation for relieving post-procedural abdominal discomfort (abdominal pain and distension). The aim of the present study was to evaluate the effect of CO2 insufflation on the remission of abdominal discomfort and the potential side effects by conducting a meta-analysis.

Methods

The method recommended by the Cochrane Collaboration was employed to conduct a meta-analysis of randomised controlled trials (RCTs) of CO2 insufflation versus air insufflation during ERCP. The PubMed, EMBASE, Cochrane Library, ISI Web of Science and China Biology Medicine disc (CBMdisc) databases were comprehensively searched.

Results

Nine high-quality RCTs were reviewed. The updated meta-analysis showed that the CO2 groups achieved a lower abdominal pain score [1-hour (SMD: −1.44, 95% CI: −2.76, −0.15), 3-hour (SMD: −1.17, 95% CI: −2.18, −0.16) and 6-hour (SMD: −1.39, 95% CI: −2.68, −0.10)], a lower abdominal distension score [1-hour (SMD: −1.05, 95% CI: −1.73, −0.38), 3-hour (SMD: −0.63, 95% CI: −1.10, −0.16) and 6-hour (SMD: −0.54, 95% CI: −0.99, −0.08)] and a lower overall rate of complications (OR: 0.59; 95% CI: 0.37, 0.93). There was no significant difference between the groups regarding abdominal discomfort immediately after recovery or 24-hour post-procedure. There was no evidence to indicate higher pressure of CO2 (pCO2) values in the CO2 groups during the procedure when the patients were under sedation anaesthesia.

Conclusions

Compared to air insufflation, CO2 insufflation is currently the preferred method for ERCP and decreases post-procedural abdominal pain and distension without significant side effects.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 41 - N° 2

P. 217-229 - mars 2017 Regresar al número
Artículo precedente Artículo precedente
  • Thalidomide is a therapeutic agent that is effective in inducing and maintaining endoscopic remission in adult CD patients
  • Zhenhua Zhu, Mengling Li, Xu Shu, Aiping Bai, Shunhua Long, Dongsheng Liu, Nonghua Lu, Xuan Zhu, Wangdi Liao
| Artículo siguiente Artículo siguiente
  • Relationship between NR1I2 polymorphisms and inflammatory bowel disease risk: A systematic review and meta-analysis
  • Man-Yi Sun, Jing-Na Lin

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.