Suscribirse

Evaluation of tumor response to intra-arterial chemoembolization of hepatocellular carcinoma: Comparison of contrast-enhanced ultrasound with multiphase computed tomography - 04/03/17

Doi : 10.1016/j.diii.2016.09.002 
S.B. Paul a, , E. Dhamija a, S.R. Gamanagatti a, V. Sreenivas b, D.P. Yadav c, S. Jain c,  Shalimar a, S.K. Acharya c
a Department of Radiodiagnosis, All India Institute of Medical Sciences (AIIMS), New Delhi 110029, India 
b Department of Biostatistics, All India Institute of Medical Sciences (AIIMS), New Delhi 110029, India 
c Department of Gastroenterology, All India Institute of Medical Sciences (AIIMS), New Delhi 110029, India 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To compare the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) with that of multiphase computed tomography (CT) in the evaluation of tumor response to transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC).

Material and methods

Fifty patients (41 men, 9 women; mean age, 53 years±12.5 [SD]) with a total of 70 HCCs (mean size, 5cm±3 [SD]) were evaluated. Post-TACE therapeutic assessment of HCC was done at 4 weeks. Patients with TACE done earlier and reporting with suspicion for recurrence were also included. Patients with hepatic masses seen on ultrasound were enrolled and subjected to CEUS, multiphase CT and magnetic resonance imaging (MRI). Hyperenhancing area at the tumor site on arterial phase of CEUS/multiphase CT/MRI was termed as residual disease (RD), the patterns of which were described on CEUS. Diagnostic accuracies of CEUS and MPCT were compared to that of MRI that was used as the reference standard.

Results

CEUS detected RD in 43/70 HCCs (61%). RD had a heterogeneous pattern in 22/43 HCCs (51%). Sensitivities of CEUS and multiphase CT were 94% (34/36; 95% CI: 81–99%) and 50% (18/36; 95% CI: 33–67%) respectively. Significant difference in sensitivity was found between CEUS and multiphase CT (P=0.0001). CEUS and multiphase CT had 100% specificity (95% CI: 83–100%).

Conclusion

CEUS is a useful technique for detecting RD in HCC after TACE. For long term surveillance, CEUS should be complemented with multiphase CT/MRI for a comprehensive evaluation.

El texto completo de este artículo está disponible en PDF.

Keywords : Contrast-enhanced ultrasound, Multiphase computed tomography (CT), Hepatocellular carcinoma, Trans-arterial chemoembolization, Comparative studies


Esquema


© 2016  Éditions françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 98 - N° 3

P. 253-260 - mars 2017 Regresar al número
Artículo precedente Artículo precedente
  • Subchondral linear hyperintensity of the femoral head: MR imaging findings and associations with femoro-acetabular joint pathology
  • P.A. Gondim Teixeira, K.-M. Savi de Tovi, W. Abou Arab, A. Raymond, M. Louis, K. Polet Lefebvre, A. Blum
| Artículo siguiente Artículo siguiente
  • Preoperative grading of supratentorial gliomas using high or standard b-value diffusion-weighted MR imaging at 3T
  • M.M. Cihangiroglu, E. Ozturk-Isik, Z. Firat, O. Kilickesmez, A.M. Ulug, U. Ture

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.