Fixation of 4-part fractures of the proximal humerus: Can we identify radiological criteria that support locking plates or IM nailing? Comparative, retrospective study of 107 cases - 01/12/16
SOFCOTf
Abstract |
Introduction |
No objective criteria exist to help surgeons choose between IM nailing and plate fixation for 4-part fractures of the proximal humerus. The goal of this study was to identify radiological criteria that would make one technique a better choice than the other.
Material and methods |
This was a comparative, multicentre, retrospective study of 54 cases of antegrade nailing and 53 cases of plating performed between 1st January 2009 and 31 December 2011 for 4-part fractures of the proximal humerus. All patients had a minimum radiological and clinical follow-up of 18 months. The functional outcomes were evaluated using the weighted Constant score; a poor result was defined as a weighted Constant score<70%. The following radiological criteria were evaluated during the preoperative assessment and at the last follow-up: initial displacement and reduction of humeral head and tuberosities; morphology of the medial column (i.e. calcar comminution, posteromedial hinge, size of metaphyseal head extension); occurrence of avascular necrosis (AVN).
Results |
After an average follow-up of 42 months, the weighted Constant scores and rate of poor outcomes were 77% and 48% in the nail group and 81% and 38% in the plate group, respectively (ns). The humeral head was reduced into an anatomical position, valgus or varus in 57%, 30% and 13% of cases in the nail group, and 58%, 29% and 13% in the plate group, respectively. The tuberosities healed in an anatomical position in 72% of nail cases and 70% of plate cases (ns). Only the presence of a medial hinge preoperatively had an effect on the functional outcomes in the nail and plate groups: the weighted Constant scores (P=0.05) and rate of poor outcomes (P=0.02) were 82% and 52% in the nail group and 97% and 9% in the plate group, respectively. The complication rates were comparable: the rates of AVN and articular screw penetration were 17% and 11% in the nail group, and 15% and 11% in the plate group, respectively. The surgical revision rate was 18.5% in the nail group and 30% in the plate group.
Conclusion |
If the medial hinge is preserved, we recommend locking plate fixation. In other cases, either technique can be used as long as the general rules of internal fixation are applied: reduction of the tuberosities, varus correction and stabilization of the calcar area.
Level of evidence |
IV, retrospective study.
El texto completo de este artículo está disponible en PDF.Keywords : Shoulder, Proximal humerus fracture, 4-part fracture, Antegrade nailing, Locking plate
Esquema
Vol 102 - N° 8
P. 963-970 - décembre 2016 Regresar al númeroBienvenido a EM-consulte, la referencia de los profesionales de la salud.