Safe zone for transacetabular screw fixation using a Kerboull cross-plate: A CT-scan templating prospective study - 01/12/16

Doi : 10.1016/j.otsr.2016.09.017 
T. Ohmori, T. Kabata , Y. Kajino, K. Hasegawa, D. Inoue, H. Tsuchiya
 Department of Orthopedic Surgery, Graduate School of Medical Science, Kanazawa University, Takaramachi 13-1, 920-8641 Kanazawa Ishikawa Japan 

Corresponding author. Tel.: +81 76 265 2374; fax: +81 76 234 4261.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Implantation of Kerboull acetabular reinforcement cross-plates (Kerboull plate) carries a risk for injury to vascular structures and pelvic organs. To our knowledge, there is no study assessing anatomical assessment related to this risk with this specific design. Therefore, we performed a prospective study to answer the following four questions: 1) What is the minimum distance and angle between the plate and iliac vessels? 2) What is the distance between the plate and the inner cortex of the ilium? 3) What is the ratio of views with muscle tissue present on the inner surface of the ilium? 4) What are the boundaries of the safe zone for transacetabular screw fixation for a Kerboull plate?

Hypothesis

A safe zone for fixation screws would be defined by a narrow range of insertion angles.

Materials and methods

This is a CT-based 3D templating prospective study. Simulations were performed for 18 patients fitted with a Kerboull plate. An original Kerboull plate (Stryker, Mahwah, NJ, USA) was placed at a 45° abduction angle relative to the X-axis (alignment A) and the palette was placed vertically to the X-axis (alignment B). We measured the distance from the centre of the plate to the inner surface of the cortex of the ilium, the shortest distance to vessels and the angle of existing vessels, and the ratio of muscles on the inner surface of the ilium.

Results

The shortest distance to the vascular structures increased with increasing angle of insertion of the fixation screws, 85.8±12.1mm for A and 111.4±12.0mm for B at 45°. The distance to the inner cortex was further increased for screws inserted in posterior direction. At insertion angles ≥40°, the screws passed through muscle before invading the pelvis in most cases. However, at anterior-posterior angle (AP angles) ≤−10°, the risk of direct insertion of screws into the sacroiliac joint increased.

Discussion

The safe zone for transacetabular screws would be insertion at an angle40°, with an AP angle between 0° and −10° (slight posterior direction).

Level of evidence

Level IV prospective diagnostic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Kerboull acetabular reinforcement cross-plate, Vascular lesions, Nerve lesions, Safe zone, Optimal length of screws, CT-based 3D templating


Esquema


© 2016  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 8

P. 1017-1022 - décembre 2016 Regresar al número
Artículo precedente Artículo precedente
  • Pelvic fracture in multiple trauma: A 67-case series
  • M. Caillot, E. Hammad, M. Le Baron, V. Villes, M. Leone, X. Flecher
| Artículo siguiente Artículo siguiente
  • Scoring system to predict hemorrhage in pelvic ring fracture
  • T. Ohmori, T. Matsumoto, T. Kitamura, R. Tamura, K. Tada, T. Inoue, T. Hayashi, K. Numoto, T. Tokioka

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.