Suscribirse

Total knee arthroplasty revision with trabecular tantalum cones: Preliminary retrospective study of 51 patients from two centres with a minimal 2-year follow-up - 09/05/16

Doi : 10.1016/j.otsr.2016.02.010 
D. Girerd a, S. Parratte a, , A. Lunebourg a, F. Boureau b, c, M. Ollivier a, G. Pasquier b, c, S. Putman b, c, H. Migaud b, c, J.N. Argenson a
a Université Aix-Marseille, Hôpital Sainte-Marguerite, Institut du Mouvement et de l’appareil Locomoteur, Service de chirurgie orthopédique et traumatologie, UMR CNRS 787/AMU, 270, boulevard Sainte-Marguerite, 13009 Marseille, France 
b Centre Hospitalier Régional Universitaire, Service de chirurgie orthopédique et traumatologie, avenue Oscar-Lambret, 59037 Lille cedex, France 
c Université de Lille, rue Paul-Duez, 59000 Lille, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Successful management of large bone defects is of crucial importance when performing revision total knee arthroplasty (TKA). Trabecular tantalum cones may improve prosthesis fixation via their potential for reconstructing a stable metaphyseal support. The objective of this study was to evaluate the clinical and radiological outcomes and the complications of tantalum cones in revision TKA.

Hypothesis

Trabecular tantalum cones provide stable and durable metaphyseal reconstruction when used during revision TKA.

Material and methods

Trabecular Metal™ cones (Zimmer, Warsaw, IN, USA) were used for 52 revision TKAs in 51 patients (mean age, 68±9 years) managed in two centres between 2008 and 2013. A rotating hinge prosthesis was chosen for 38 (73%) knees and a condylar constrained knee prosthesis for 14 (27%) knees, with 37 tibial and 34 femoral cones. The two most common reasons for revision surgery were aseptic loosening (n=22, 42%) and infection (n=19, 37%). The bone loss was severe in most cases. At each centre, after a mean follow-up of 34 months (range, 24–52 months), two independent observers assessed the Knee Society Score (KSS), range of motion, mechanical axis, and osteo-integration for each patient.

Results

Mean KSS increased from 46 preoperatively to 77 (P=0.001) at last follow-up and the mean KSS function from 39 to 57 (P=0.007). Mean range of motion improved from 93° (45°–120°) to 110° (65°–130°) (P=0.001). Mean postoperative mechanical axis was 180° (172°–190°). Radiographic evaluation showed evidence of osteo-integration for all cones. Four revisions were performed for recurrence of infection but none for mechanical failure.

Discussion

The findings of our study confirm the biomechanical and biological reliability of Trabecular Metal™ cones used to fill metaphyseal bone defects during revision TKA.

Level of evidence

IV, retrospective therapeutic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Revision, Total knee arthroplasty, Knee, Trabecular metal cones, Tantalum, Bone defect


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 4

P. 429-433 - juin 2016 Regresar al número
Artículo precedente Artículo precedente
  • Reproducibility of digital measurements of lower-limb deformity on plain radiographs and agreement with CT measurements
  • G. Sorin, G. Pasquier, E. Drumez, A. Arnould, H. Migaud, S. Putman
| Artículo siguiente Artículo siguiente
  • Joint awareness after total knee arthroplasty is affected by pain and quadriceps strength
  • Y. Hiyama, O. Wada, S. Nakakita, K. Mizuno

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.