Comparison of intraoperative flat panel imaging and postoperative plain radiography for the detection of intraarticular screw displacement in volar distal radius plate ostheosynthesis - 08/12/15

Doi : 10.1016/j.otsr.2015.07.023 
J. Borggrefe a, b, , H. Bolte a, c, W. Worms d, L. Mahlke e, A. Seekamp d, L. Menzdorf d, D. Varoga d, M. Müller d, M. Weuster d, D. Zorenkov f, T. Wedel g, S. Lippross d
a University medical center of Schleswig-Holstein, Campus Kiel, Kiel, Germany 
b Department of radiology, Uniklinik Köln, Köln, Germany 
c Department of nuclear medicine, university-Clinics Münster, Münster, Germany 
d Department of trauma surgery, university medical center of Schleswig-Holstein, Campus Kiel, Kiel, Germany 
e Saint-Vincenz hospital, Paderborn, Germany 
f Department of neurology, university medical center of Schleswig-Holstein, Campus Kiel, Kiel, Germany 
g Department of anatomy, Christian-Albrecht-aniversity, Kiel, Germany 

Corresponding author. Kerpenerstr. 62, 50937 Germany. Tel.: +49 221 478 82006; fax: +49 221 478 82381.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Objectives

To investigate if intraoperative 3D flat panel imaging improves the detection of radiocarpal intraarticular screw misplacement (RCSM) in comparison to standard postoperative x-ray.

Methods

In a study on cadaver specimens, we evaluated the sensitivity and specificity to detect RCSM using X-ray, intraoperative 3D-fluoroscopy as well as the digital volume tomography. The gold standard reference was computed tomography.

Results

Sensitivity for the detection of RCSM for X-ray was 58% and specificity 88%. For DVT, the sensitivity to detect RCSM was 88% and the specificity 53%. For 3D-fluoroscopy, the sensitivity for RCSM was 68% and specificity 95%. When combining the methods, the best performance was found, when combining the two intraoperative imaging methods, with a resulting sensitivity of 88% and a specificity of 73%.

Conclusions

Intraoperative 3D fluoroscopy and digital volume tomography appear to be at least as sensitive and specific to detect RCSM than the regular postoperative radiography in two planes. However, especially discrete screw misplacements can be missed with either method.

Level of evidence

Level IV. Diagnostic device study.

El texto completo de este artículo está disponible en PDF.

Keywords : Intraarticular screw, Screw misplacement, Flat panel detector, Intraoperative fluoroscopy, Radius fracture


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 8

P. 913-917 - décembre 2015 Regresar al número
Artículo precedente Artículo precedente
  • Anatomic study of the extensor carpi radialis brevis in its relation with the motor branch of the radial nerve
  • E. Vergara-Amador, A. Ramírez
| Artículo siguiente Artículo siguiente
  • Proximal row carpectomy in total arthrodesis of the rheumatoid wrist
  • T.T. Pham, H. Lenoir, B. Coulet, M. Wargny, C. Lazerges, M. Chammas

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.