S'abonner

Development and preliminary test of a new plateau hyperbaric chamber - 13/08/15

Doi : 10.1016/j.ajem.2015.06.005 
Liang Sun, MD a, b, Meng-jiang Ding, MD c, Tian-cai Cai, MD d, Hao-jun Fan, MD e, Jian-peng Zhang, MD, PhD f,
a Medical College of Chinese People's Liberation Army General Hospital, Teaching center Building, No. 28, Fu-Xing Road, Haidian District, Beijing, 100853, China 
b Department of Respiratory and Critical Care Medicine of Ping Jin Hospital, Affiliated Hospital of Logistic University of Chinese People's Armed Police Force, No. 220, Cheng-Lin Road, Tianjin, 300162, China 
c Tianjin Municipal Corps Hospital of Chinese People's Armed Police Forces, No. 206,Wei-guo Road, Tianjin, 300162, China 
d Xiamen Sanatorium of Chinese people's Armed Police Forces, No. 189,Two West Zeng Cuo Road, Siming District, Xiamen, China 
e Institute of Disaster Medicine and Public Health, Affiliated Hospital of Logistic University of Chinese People's Armed Police Force, No. 220, Cheng-Lin Road, Tianjin, 300162, China 
f Department of Respiratory, General Hospital of Chinese People's Armed Police Force, No. 69, Yong-ding Road, Haidian District, Beijing, 100039, China 

Corresponding author. Tel.: +86 22 60578941; fax: +86 22 60578671.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 13 August 2015

Abstract

Objective

The objective of this study is to validate the performance, define its limits, and provide details on a new plateau hyperbaric chamber at 355-, 2880-, and 4532-m high altitude.

Methods

A new multiplace plateau hyperbaric chamber was designed to satisfy the needed of patients who have acute mountain sickness. Tests were conducted inside the chamber at 355-, 2880-, and 4532-m high altitude. The safely and conveniences of the new plateau hyperbaric chamber were estimated.

Results

Minimum pressures of the main compartment can reach up to 0.029, 0.022, and 0.02 MPa at 355-, 2880-, and 4532-m high altitude. During pressurization, there was no leak of air around the chamber. The time lag of pressure equilibration between main and buffer compartment varies from 30.3 ± 2.01 to 200.5 ± 5.44 seconds and between buffer compartment and ambient pressure varies from 60.2 ± 4.13 to 215.9 ± 6.76 seconds.

Conclusions

The chamber can be applicated for acute mountain sickness treatment safety and convenience. However, further experience about animals and human within the chamber is needed to improve the hardware and establish conditions of effective utilization of this equipment in the high altitude.

Le texte complet de cet article est disponible en PDF.

Plan


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.