Comparison of gadofosveset (Vasovist®) with gadobenate dimeglumine (Multihance®)-enhanced MR angiography for high-grade carotid artery stenosis - 02/07/15
pages | 9 |
Iconographies | 1 |
Vidéos | 0 |
Autres | 0 |
Summary |
Objective |
To prove superiority of blood pool contrast agent gadofosveset over conventional contrast agent gadobenate dimeglumine for assessment of stenotic internal carotid artery (ICA).
Methods |
Eleven patients with high-grade ICA stenosis (≥75%), confirmed by duplex sonography, underwent MR angiography (MRA) with gadofosveset and gadobenate dimeglumine.
Results |
Agreement in stenosis grade was reached in 7 of 10 stenotic ICAs. In two ICAs, gadobenate dimeglumine led to underestimation of stenosis grade. There was a significant difference in signal intensity (pre-/post-stenotic segments), showing higher values for gadofosveset (P<0.01; P<0.05). Impression of contrast intensity with gadofosveset was better in 8 ICAs and only in 1 ICA with gadobenate dimeglumine (P<0.05).
Conclusion |
Gadofosveset-enhanced MR angiography may be superior for assessment of high-grade ICA stenosis compared with gadobenate dimeglumine MR angiography.
Le texte complet de cet article est disponible en PDF.Keywords : Magnetic resonance imaging, Gadofosveset, Gadobenate dimeglumine, Carotid artery stenosis
Plan
Vol 42 - N° 4
P. 236-244 - juillet 2015 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.