Impact of device selection and clip duration on lung ultrasound assessment in patients with heart failure - 29/06/15

Doi : 10.1016/j.ajem.2015.06.002 
Elke Platz, MD, MS a, , 1 , Emanuele Pivetta, MD, MSc b, 1, Allison A. Merz, BA a, c, Julie Peck, BA a, c, Jose Rivero, MD c, Susan Cheng, MD, MSc, MPH c
a Department of Emergency Medicine, Brigham and Women’s Hospital, 75 Francis Street, Boston, MA 02115, USA 
b Department of Medical Sciences, Division of Emergency Medicine and Cancer Epidemiology Unit, “Città della Salute e della Scienza di Torino”, Hospital and the University of Turin, Turin, Italy 
c Cardiovascular Division, Brigham and Women’s Hospital, 75 Francis Street, Boston, MA 02115, USA 

Corresponding author at: Department of Emergency Medicine, Brigham and Women’s Hospital, 75 Francis Street, Neville House, Boston, MA 02115, USA. Tel.: +1 617 525 7932; fax: +1 617 713 3060.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Monday 29 June 2015
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Objectives

Pulmonary edema is a common sign of heart failure and can be quantified by counting vertical artifacts (B-lines) on lung ultrasound (LUS). The primary aim of this study was to compare a pocket size ultrasound device to high-end ultrasound systems on the measured number of B-lines. We also compared the impact of different-length ultrasound clips on the measured number of B-lines.

Methods and results

We studied 21 hospitalized patients with heart failure (81% men; median age, 73; 71% Caucasian) who underwent concurrent 8- and 4-zone LUS using both a pocket ultrasound device and a high-end ultrasound system. For the 4-zone scanning method, the median B line number was 2 (interquartile range, 1-4) for the pocket device and 3 (1-5) for the high-end system (P = .67). For the 8-zone method, the median B-line number was 4 (2-7) for the pocket device and 5 (3-7) for the high-end system (P = .18). A higher number of B-lines was identified on the 4- vs 2-second LUS clips (P < .001 for 4 zones, P = .001 for 8 zones), and on the 6- vs 4-second LUS clips (P=0.057 for 4 zones, P=0.018 for 8 zones).

Conclusions

Our findings suggest significant differences based on LUS clip duration rather than the type of ultrasound device used, with respect to the number of B-lines detectable in patients with heart failure. These factors should be considered in the design and reporting of LUS studies and in longitudinal assessments of heart failure patients.

Le texte complet de cet article est disponible en PDF.

Plan


 Clinical trial registration: Not applicable.


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.