S'abonner

Supraciliary Micro-stent Implantation for Open-Angle Glaucoma Failing Topical Therapy: 1-Year Results of a Multicenter Study - 07/05/15

Doi : 10.1016/j.ajo.2015.02.018 
Julian García-Feijoo a, Magda Rau b, Swaantje Grisanti c, Salvatore Grisanti d, Helmut Höh e, f, Carl Erb g, Pravoslava Guguchkova h, Iqbal Ahmed i, Günther Grabner j, Herbert Reitsamer j, Tarek Shaarawy k, Tsontcho Ianchulev l,
a Instituto de Investigación, Biomedica Hospital Clinico San Carlos, UCM, Oftared, Madrid, Spain 
b Eye Clinic, Cham, Germany 
c University Clinic Schleswig-Holstein, Luebeck, Germany 
d Eye Hospital, Luebeck, Germany 
e Eye Hospital at the Dietrich-Bonhoeffer-Klinikum, Neubrandenburg, Germany 
f Teaching Hospital of the Ernst-Moritz-Arndt University of Greifswald, Greifswald, Germany 
g Eye Clinic Wittenbergplatz, Berlin, Germany 
h Eye Clinic of Sofia, Sofia, Bulgaria 
i University of Toronto, Toronto, Canada 
j Paracelsus Medical University, Salzburg, Austria 
k University of Geneva, Geneva, Switzerland 
l University of California at San Francisco, San Francisco, California 

Inquiries to Tsontcho Ianchulev, 127 Independence Drive, Menlo Park, CA 94025

Abstract

Purpose

To evaluate the safety and efficacy of a supraciliary micro-stent (CyPass Micro-Stent; Transcend Medical, Menlo Park, California, USA) for surgical treatment of glaucoma in patients refractory to topical medications.

Design

Multicenter, single-arm interventional study.

Methods

Patients with open-angle glaucoma (Shaffer Grade 3 and 4) and uncontrolled medicated intraocular pressure (IOP) >21 mm Hg at baseline and candidates for conventional glaucoma surgery were enrolled. Glaucoma medications were discontinued at surgery and resumed at investigator discretion. CyPass Micro-Stent implantation was completed in all patients using a standard clear corneal approach. Adverse events, postoperative IOP changes, and need for IOP-lowering medications during the first 12 postoperative months (12M) were monitored.

Results

Sixty-five eyes were enrolled, and 55 were available at 12M, accounting for loss to follow-up and early termination. Baseline IOP was 24.5 ± 2.8 mm Hg, and the mean number of medications recorded was 2.2 ± 1.1. There were no serious intraoperative events or major adverse events (eg, retinal or choroidal detachment, persistent uveitis, persistent hyphema, hypotony maculopathy). The most common adverse events included IOP increases >30 mm Hg beyond 1 month (11%, 7/65), transient hyphema (6%, 4/65), and cataract progression (12%, 5/41 phakic eyes). Mean IOP was 16.4 ± 5.5 mm Hg at 12 months—a 34.7% reduction (P < .0001). Mean medication usage also decreased from baseline to a mean of 1.4 ± 1.3 medications at 12M (P = .002). In eyes originally indicated for conventional glaucoma surgery, no secondary surgery was performed in 83% (53/64).

Conclusion

Supraciliary stenting with the CyPass Micro-Stent effectively lowers IOP as a surgical treatment for glaucoma, precluding the need for more invasive glaucoma surgery in >80% of patients at 1 year, thereby reducing postoperative glaucoma surgical complications.

Le texte complet de cet article est disponible en PDF.

Plan


© 2015  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 159 - N° 6

P. 1075 - juin 2015 Retour au numéro
Article précédent Article précédent
  • Intraocular Medulloepitheliomas and Embryonal Tumors With Multilayered Rosettes of the Brain: Comparative Roles of LIN28A and C19MC
  • Frederick A. Jakobiec, Marcel Kool, Anna M. Stagner, Stefan M. Pfister, Ralph C. Eagle, Alan D. Proia, Andrey Korshunov
| Article suivant Article suivant
  • Long-Term Bleb-Related Infections After Trabeculectomy: Incidence, Risk Factors, and Influence of Bleb Revision
  • Eun-Ah Kim, Simon K. Law, Anne L. Coleman, Kouros Nouri-Mahdavi, JoAnn A. Giaconi, Fei Yu, Ji-Woong Lee, Joseph Caprioli

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.