S'abonner

Computed tomography scan versus upper gastrointestinal fluoroscopy for diagnosis of staple line leak following bariatric surgery - 05/05/15

Doi : 10.1016/j.amjsurg.2015.01.004 
Jason Bingham, M.D. , Robert Shawhan, M.D., Ross Parker, M.D., Jay Wigboldy, M.D., Vance Sohn, M.D.
 Department of General Surgery, Madigan Army Medical Center, 9040 Fitzsimmons Drive, Tacoma, WA 98431, USA 

Corresponding author. Tel.: +1-253-968-5007; fax: (253) 968-5009.

Abstract

Background

The best radiographic modality to diagnose staple line leaks following bariatric surgery remains controversial. Two common studies used are upper gastrointestinal (UGI) fluoroscopy and computed tomography (CT). This study sought to determine the better modality in detecting clinically significant postoperative leaks.

Methods

This retrospective review was performed of patients undergoing imaging for suspected staple line leaks following bariatric surgery. These studies were reinterpreted by 2 radiologists who were blinded to the original findings.

Results

Six hundred nineteen radiographic “leak tests” were selectively performed following bariatric procedures at our institution between January 2005 and December 2011. CT was found to have a sensitivity of 95% (95% confidence interval [CI] 81.8 to 99.1) and a specificity of 100% (95% CI 93.1 to 100) in diagnosing postoperative leaks, while UGI demonstrated a sensitivity of 79.4% (95% CI 61.6 to 90.0) and a specificity of 95% (95% CI 85.2 to 98.7).

Conclusion

CT is a superior modality compared with UGI for detecting staple line leaks following bariatric surgery.

Le texte complet de cet article est disponible en PDF.

Keywords : Bariatric surgery, Anastomotic leak, Computed tomography, Upper GI fluoroscopy


Plan


 The authors declare no conflicts of interest.
 The views expressed are those of the author(s) and do not reflect the official policy of the Department of the Army, the Department of Defense, or the U.S. Government.


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 209 - N° 5

P. 810-814 - mai 2015 Retour au numéro
Article précédent Article précédent
  • Can general surgeons evaluate visceral slide with transabdominal ultrasound to predict safe sites for primary laparoscopic port placement? A prospective study of sonographically naïve operators at a tertiary center
  • Samuel Minaker, Cailan MacPherson, Allen Hayashi
| Article suivant Article suivant
  • A population-based comparison of open versus minimally invasive abdominoperineal resection
  • Andrew T. Schlussel, Michael B. Lustik, Eric K. Johnson, Justin A. Maykel, Brad J. Champagne, Joel E. Goldberg, Scott R. Steele

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.