S'abonner

Détection des tumeurs T1 et T2 des voies aérodigestives supérieures : comparaison des performances diagnostiques en IRM et en TEP/TDM-FDG - 05/12/14

Doi : 10.1016/j.mednuc.2014.09.003 
M. Ollivier a , N. Keromnès b, V. Tissot a, P. Robin b, R. Abgral b, M. Nonent c, P.Y. Salaun b, , M. Gouillou d, J. Rousset e
a Service d’imagerie médicale, hôpital Morvan, CHRU de Brest, 2, avenue Foch, 29609 Brest cedex, France 
b Service de médecine nucléaire, hôpital Morvan, CHRU de Brest, 2, avenue Foch, 29609 Brest cedex, France 
c Service d’imagerie médicale, hôpital de la Cavale-Blanche, CHRU de Brest, boulevard Tanguy-Prigent, 29609 Brest cedex, France 
d Centre d’investigation clinique, CHRU de Brest, boulevard Tanguy-Prigent, 29609 Brest cedex, France 
e Service d’imagerie médicale, hôpital d’instruction des armées Clermont-Tonnerre, rue du Colonel-Fonferrier, 29200 Brest, France 

Auteur correspondant : Service d’imagerie oncologique, 2, avenue Foch, 29609 Brest cedex, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

Les tumeurs des voies aérodigestives supérieures (VADS) classées T1 et T2, du fait de leur petite taille, sont plus difficiles à diagnostiquer en imagerie que les tumeurs de stade plus élevé. Le but de cette étude était d’évaluer et de comparer la performance diagnostique de la TEP/TDM-FDG et de l’IRM dans la détection des tumeurs de petite taille des VADS.

Patients et méthodes

Une étude rétrospective a été menée sur 21 patients présentant des tumeurs histologiquement prouvées des VADS, T1 ou T2 selon la classification TNM, ayant bénéficié d’une IRM et d’une TEP/TDM-FDG préthérapeutiques. La capacité de détection tumorale était évaluée en IRM et en TEP/TDM-FDG à l’aide d’une échelle qualitative. Les sensibilités des deux modalités d’imagerie étaient comparées entre elles. Le SUVmax et le pourcentage de rehaussement étaient mesurés pour chaque tumeur et analysés en fonction du classement T.

Résultats

Parmi les 21 tumeurs, 17 étaient retrouvées en TEP/TDM-FDG contre 12 en IRM. Aucune des 4 lésions non identifiées en TEP/TDM-FDG n’était visible en IRM. La TEP/TDM-FDG avait correctement identifié 5 des 9 résultats faux-négatifs de l’IRM. La sensibilité de la TEP/TDM-FDG était de 80,9 % contre 57,1 % pour l’IRM, à la limite de la significativité statistique (p=0,06). Il n’a pas été retrouvé de corrélation significative entre le SUVmax et le classement T.

Conclusion

La TEP/TDM-FDG peut être utile pour l’identification de localisations tumorales primitives des VADS, même de petite taille, classées T1 ou T2, avec une sensibilité supérieure à celle de l’IRM.

Le texte complet de cet article est disponible en PDF.

Abstract

Objective

Extracranial head and neck tumors classified T1 and T2, because of their small size, are more difficult to diagnose by imaging than the tumors of higher stage. The aim of this study is to evaluate and compare FDG-PET/CT and MRI accuracy for detection of small extracranial head and neck tumors.

Materials and methods

A retrospective study was led on 21 patients having a histopathologically proven tumors involving the upper aerodigestive tract, classified T1 or T2 according to TNM staging, which received pre-therapeutic MRI and FDG-PET/CT. Tumoral detection ability was estimated on MRI and FDG-PET/CT by a qualitative scale. Sensitivities of the two methods of imaging were compared between then. The SUVmax and the percentage of enhancement were measured for each tumor and analysed according to T staging.

Results

Among the 21 tumors, 17 were detected by FDG-PET/CT against 12 by MRI. None of the 4 unidentified lesions by FDG-PET/CT was visible on MRI. FDG-PET/CT correctly identified 5 of the 9 MRI false-negative results. The sensitivity was 80.9 % for FDG-PET/CT and 57.1 % for MRI, on the verge of the statistically significant difference (P=0.06). There was no significant correlation of the SUVmax to the T staging.

Conclusion

FDG-PET/TDM could be useful for the identification of primary extracranial head and neck tumors, even small-sized, classified T1 or T2, with a sensitivity higher than MRI.

Le texte complet de cet article est disponible en PDF.

Mots clés : Tumeurs des VADS, IRM, TEP-scan, Sensibilité

Keywords : Head and neck cancer, MRI, PET/CT, Sensitivity


Plan


© 2014  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 38 - N° 6

P. 419-428 - décembre 2014 Retour au numéro
Article précédent Article précédent
  • Comparaison de différents indices métaboliques et de la méthode SULTAN dans l’évaluation de la réponse thérapeutique par TEP au 18FDG dans le cancer du sein métastatique
  • D. Goulon, C. Rousseau, H. Necib, T. Carlier, B. Hennaf, D. Rusu, M. Lacombe, M. Colombie, F. Kraeber-Bodere
| Article suivant Article suivant
  • Segmentation d’images de lésions cérébrales primitives en TEP FET : influence du volume de travail
  • C. Lemarignier, J. Kraft, R. Modzelewski, T. Fechter, I. Gardin, I. Götz, A. Grosu, P. Vera, U. Nestle

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.