S'abonner

Accurate and reliable 3-lead to 12-lead ECG reconstruction methodology for remote health monitoring applications - 02/12/14

Doi : 10.1016/j.irbm.2014.07.004 
S. Maheshwari a , A. Acharyya b, , P. Rajalakshmi c , P.E. Puddu d , M. Schiariti d
a Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, India 
b Room No. 28, Department of Electrical Engineering, Indian Institute of Technology (IIT), Hyderabad, Ordnance Factory Estate, Medak, Yeddumailaram 502205, Andhra Pradesh, India 
c Wireless Networks (WiNeT) Lab, Department of Electrical Engineering, Indian Institute of Technology Hyderabad, ODF Campus, Yeddumailaram 502205, India 
d Department of Cardiovascular Sciences, Tract, Nephrology, Anaesthesiology and Geriatric, University of Rome “La Sapienza”, Italy 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 6
Vidéos 0
Autres 0

Abstract

Remote areas, generally, encounter scarcity of cardiologists and state-of-the-art facilities for the treatment of cardiovascular diseases (CVD). However, aforementioned constraints can be addressed using recent advancements in wireless technology and its omnipresence. Clinical CVD diagnosis is, generally, carried out using either of Standard 12-Lead (S12) or Mason–Likar 12-Lead (ML12) system. These systems consist of 8 independent leads/signals which restrict their usage in telemonitoring applications viz. personalized remote health monitoring, home monitoring etc., due to high bandwidth and storage requirements, data transmission time and low compression ratio (CR) from signal compression techniques. Moreover, the reduced lead (RL) systems with 2–3 leads, generally, employed in telemonitoring applications might not be sufficient for diagnosis. We form a Reduced 3-Lead system from S12 and ML12 systems at the transmission end which reduces the number of signals to 3 and then reconstruct the S12 and ML12 systems at the receiver end using our proposed personalized reconstruction methodology, thus allaying aforementioned limitations. I, II and   form the basis leads and the precordial leads form the target leads. Least square fit and heart vector projection theory have been used to obtain personalized transformation coefficients. Accuracy of reconstruction has been evaluated on PhysioNet PTBDB and INCARTDB, after wavelet based preprocessing, using   statistics, correlation ( ) and regression ( ) coefficients. Re-usability of personalized coefficients has also been investigated in this paper. Mean   values obtained from the reconstruction of target leads are 91.87% (PTBDB) 83.75% (INCARTDB). R3L system reduces the number of leads/signals from 8 to 3 and as the results indicate the possibility of re-using the transformation coefficients, the number of electrodes can be reduced from 10 to 5, thereby, increasing the comfort of patients and caregivers.

Le texte complet de cet article est disponible en PDF.

Plan


© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 35 - N° 6

P. 341-350 - décembre 2014 Retour au numéro
Article précédent Article précédent
  • Using load cells under the bed as a non-contact method for detecting periodic leg movements
  • A.M. Adami, A.G. Adami, T.L. Hayes, Z.T. Beattie
| Article suivant Article suivant
  • Discrete-wavelet-transform-based noise removal and feature extraction for ECG signals
  • H.-Y. Lin, S.-Y. Liang, Y.-L. Ho, Y.-H. Lin, H.-P. Ma

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.