The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: Prospective study with the EOS imaging system - 02/10/14

Doi : 10.1016/j.otsr.2014.07.003 
O. Barbier a, b, c, , W. Skalli b, L. Mainard d, D. Mainard a

Computer Assisted Orthopedic Surgery–France (CAOS-France)Professeur E. Stindel, service orthopédie traumatologie, CHU de Brest, hôpital de la Cavale-Blanche, boulevard Tanguy-Prigent, 29609 Brest cedex, France

a Service de chirurgie orthopédique, hôpital central, 29, avenue de Lattre-de-Tassigny, 54000 Nancy, France 
b Laboratoire de biomécanique, école nationale supérieure des arts et métiers Paris tech, boulevard de l’Hôpital, 75013 Paris, France 
c Service de chirurgie orthopédique, hôpital d’instruction des Armées-Bégin, 69, avenue de Paris, 94160 Saint-Mandé, France 
d Service de radiologie, hôpital Brabois, rue du Morvan, 54511 Vandœuvre-lès-Nancy, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Computer navigated total hip arthroplasty is mostly based on the use of the anterior pelvic plane (APP) as a reference. EOS is a new imaging system that provides three-dimensional analysis of the pelvis in a functional position with a low dose of radiation. The aim of this study was to evaluate the reliability of the APP for placement of the cup during computer navigated THA using EOS.

Hypothesis

The reliability of the APP is limited for the placement of the acetabular cup during computer navigated THA.

Materials and methods

This was a prospective monocentric study using the EOS imaging system evaluating 44 patients in the standing position three months after computer navigated THA (Orthopilot™). Reproducibility of EOS measurements were analyzed using SterEOS software and the reliability of the navigation data for the position of the cup were assessed.

Results

Intra and interobserver reproducibility of the measurements of the orientation of the cup by EOS were good with correlation coefficients above 93% and 95% and confidence intervals of less than±5°. Mean cup inclination and anteversion were 41.3° and 20.9° and 44.3° and 29.5° respectively in operatively and post-operatively. The differences between measurements of operative cup inclination using computer assisted navigation and the post-operative EOS measurements were significant (P<0.05) with a correlation coefficient of less than 40%.

Discussion

Our study confirms the lack of precision of the APP as a reference for positioning of the acetabular component, especially in relation to anteversion. Although for many years the APP was considered to be a global reference, in fact, it is subject to significant inter-individual variations and variations during changes in position. These factors, associated with the difficulty of determining the preoperative APP, explain the lack of reliability of this reference. Preoperative evaluation of the orientation of APP by EOS and its integration into the navigation system could help the operator position these components.

Level of evidence

Level III Prospective diagnostic case controlled study.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, EOS, Navigation, Anterior pelvic plane


Plan


© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 6S

P. S287-S291 - octobre 2014 Retour au numéro
Article précédent Article précédent
  • 3D templating and patient-specific cutting guides (Knee-Plan®) in total knee arthroplasty: Postoperative CT-based assessment of implant positioning
  • J.-P. Franceschi, A. Sbihi, Computer Assisted Orthopedic Surgery - France (CAOS - France) b
| Article suivant Article suivant
  • The role of total elbow arthroplasty in traumatology
  • P. Mansat, N. Bonnevialle, M. Rongières, P. Bonnevialle, Bone, Joint Trauma Study Group (GETRAUM) b

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.