S'abonner

Coronary Blood Flow in Patients With Severe Aortic Stenosis Before and After Transcatheter Aortic Valve Implantation - 26/09/14

Doi : 10.1016/j.amjcard.2014.07.054 
Itsik Ben-Dor, MD, Rahul Malik, MD, Sa'ar Minha, MD, Steven A. Goldstein, MD, Zuyue Wang, MD, Marco A. Magalhaes, MD, Gaby Weissman, MD, Petros G. Okubagzi, MD, Rebecca Torguson, MD, Joseph Lindsay, MD, Lowell F. Satler, MD, Augusto D. Pichard, MD, Ron Waksman, MD
 Division of Cardiology, MedStar Washington Hospital Center, Washington, DC 

Corresponding author: Tel: (202) 877-2812; fax: (202) 877-2715.

Abstract

Patients with severe aortic stenosis and no obstructed coronary arteries are reported to have reduced coronary flow. Doppler evaluation of proximal coronary flow is feasible using transesophageal echocardiography. The present study aimed to assess the change in coronary flow in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). The left main coronary artery was visualized using transesophageal echocardiography in 90 patients undergoing TAVI using the Edwards SAPIEN valve. The peak systolic and diastolic velocities of the coronary flow and the time-velocity integral were obtained before and after TAVI using pulse-wave Doppler. Mean aortic gradients decreased from 47.1 ± 15.7 mm Hg before TAVI to 3.6 ± 2.6 mm Hg after TAVI (p <0.001). The aortic valve area increased from 0.58 ± 0.17 to 1.99 ± 0.35 cm2 (p <0.001). The cardiac output increased from 3.4 ± 1.1 to 3.8 ± 1.0 L/min (p <0.001). Left ventricular end-diastolic pressure (LVEDP) decreased from 19.8 ± 5.4 to 17.3 ± 4.1 mm Hg (p <0.001). The following coronary flow parameters increased significantly after TAVI: peak systolic velocity 24.2 ± 9.3 to 30.5 ± 14.9 cm/s (p <0.001), peak diastolic velocity 49.8 ± 16.9 to 53.7 ± 22.3 cm/s (p = 0.04), total velocity-time integral 26.7 ± 10.5 to 29.7 ± 14.1 cm (p = 0.002), and systolic velocity-time integral 6.1 ± 3.7 to 7.7 ± 5.0 cm (p = 0.001). Diastolic time-velocity integral increased from 20.6 ± 8.7 to 22.0 ± 10.1 cm (p = 0.04). Total velocity-time integral increased >10% in 43 patients (47.2%). Pearson's correlation coefficient revealed the change in LVEDP as the best correlate of change in coronary flow (R = −0.41, p = 0.003). In conclusion, TAVI resulted in a significant increase in coronary flow. The change in coronary flow was associated mostly with a decrease in LVEDP.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 1267 for disclosure information.


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 114 - N° 8

P. 1264-1268 - octobre 2014 Retour au numéro
Article précédent Article précédent
  • Early Trends in N-Terminal Pro–Brain Natriuretic Peptide Values After Left Ventricular Assist Device Implantation for Chronic Heart Failure
  • Tal Hasin, Sudhir S. Kushwaha, Timothy G. Lesnick, Walter Kremers, Barry A. Boilson, John A. Schirger, Alfredo L. Clavell, Richard J. Rodeheffer, Robert P. Frantz, Brooks S. Edwards, Naveen L. Pereira, John M. Stulak, Lyle Joyce, Richard Daly, Soon J. Park, Allan S. Jaffe
| Article suivant Article suivant
  • A Gender Based Analysis of Predictors of All Cause Death After Transcatheter Aortic Valve Implantation
  • Federico Conrotto, Fabrizio D'Ascenzo, Stefano Salizzoni, Patrizia Presbitero, Pierfrancesco Agostoni, Corrado Tamburino, Giuseppe Tarantini, Francesco Bedogni, Freek Nijhoff, Valeria Gasparetto, Massimo Napodano, Giuseppe Ferrante, Marco Luciano Rossi, Pieter Stella, Nedy Brambilla, Marco Barbanti, Francesca Giordana, Costanza Grasso, Giuseppe Biondi Zoccai, Claudio Moretti, Maurizio D'Amico, Mauro Rinaldi, Fiorenzo Gaita, Sebastiano Marra

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.