S'abonner

Color Doppler Imaging in Patients With Asymmetric Glaucoma and Unilateral Visual Field Loss - 26/08/14

Doi : 10.1016/S0002-9394(14)75424-8 
MARCELO T. NICOLELA, M.D. 1, 3, STEPHEN M. DRANCE, M.D. 1, SIMON J.A. RANKIN, F.R.C.Ophth. 1, ANNE R. BUCKLEY, F.R.C.P.C. 2, BRENDA E. WALMAN 2
1 Department of Ophthalmology, University of British Columbia, Vancouver, Canada 
2 Department of Radiology, University of British Columbia, Vancouver, Canada 
3 Department of Ophthalmology, University of São Paulo, Brazil 

Résumé

• Purpose:

To determine whether lower blood velocities and high resistive index in the retrobulbar arteries are primary or secondary to glaucomatous damage in patients with open-angle glaucoma.

• Methods:

Color Doppler imaging was performed in 32 glaucomatous patients with unilateral visual field loss and in 31 control subjects. Peak systolic velocity and end diastolic velocity were measured, and resistive index was calculated in the central retinal artery and short posterior ciliary arteries.

• Results:

In patients with glaucoma, both the more affected and the contralateral eyes with normal visual fields had significantly lower peak systolic velocity and end diastolic velocity in their central retinal artery and short posterior ciliary arteries than did the control subjects of similar age (P ≤ .03). The resistive index of the central retinal artery of both eyes of patients with glaucoma was also significantly higher than in the control subjects (P = .001). When considering the 16 patients who had the greatest visual field asymmetry, the more affected eyes had lower peak systolic velocity and end diastolic velocity in the central retinal artery than the contralateral eyes did (P = .02).

• Conclusions:

Even eyes with normal visual fields in patients with asymmetric disease had decreased blood velocities in their retrobulbar vessels, suggesting that these circulatory changes probably precede detectable damage. Furthermore, the finding of lower central retinal artery blood velocities in the more affected eye of asymmetric patients suggests that low blood velocities may be one of the lateralizing factors in those patients and that they have a possible role in the pathogenesis of the disease.

Le texte complet de cet article est disponible en PDF.

 Data from this study were presented at the Association for Research in Vision and Ophthalmology Annual Meeting, Fort Lauderdale, Florida, May 16, 1995.
Reprint requests to Stephen M. Drance, M.D., Department of Ophthalmology, University of British Columbia, F 197-2211 Wesbrook Mall, Vancouver, BC, Canada V6T 2B5.


© 1996  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 121 - N° 5

P. 502-510 - mai 1996 Retour au numéro
Article précédent Article précédent
  • Comparison Between Tomographic Scanning Evaluation and Photographic Measurement of the Neuroretinal Rim
  • ALBERT DICHTL, JOST B. JONAS, CHRISTIAN Y. MARDIN
| Article suivant Article suivant
  • Neural Networks to Identify Glaucoma With Structural and Functional Measurements
  • L. BRIGATTI, D. HOFFMAN, J. CAPRIOLI

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.