S'abonner

Feasibility and accuracy of left ventricular volumes and ejection fraction measured by different echocardiographic methods in congenital heart diseases involving the right ventricle - 24/08/14

Doi : 10.1016/j.acvd.2014.07.020 
M. Meot , D. Khraiche, M. Ladouceur, F. Raimondi, O. Guillard, D. Bonnet
 M3C-Necker Enfants malades, Université Paris-Descartes, Sorbonne Paris Cité, Paris, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Background

In CHD with RV volumetric or barometric overload, LV shape is altered. Little is known about the accuracy in this population of left ventricular (LV) volumes and ejection fraction (EF) measurement by standard echocardiographic methods using geometrical assumption: Teicholz, biplane Simpson and real-time 3D echocardiography (RT-3DE). Three-dimensional knowledge-based reconstruction (3D-KR) derived from two-dimensional echocardiographic imaging is a novel technique that has no geometrical assumption. The aim of our study is to assess the accuracy of several echocardiographic methods for measuring LV volumes and EF compared to cardiac magnetic resonance (CMR) measurements (gold standard) in this population.

Methods

68 patients (mean age 13,3±4years) with Congenital Heart Diseases (CHD) involving the RV and referred for cardiac MRI, were included. Among them, 13 patients had barometric overload, 37 patients had volumetric overload, and 18 patients had mixed overload. Echocardiographic images acquisition was performed using a standard ultrasound scanner linked to a Ventripoint Medical Systems unit. Analyzed parameters were end-diastolic volume (EDV), end-systolic volume (ESV), and LVEF measured by Teicholz, Simpson's modified formula and RT-3DE (GE Vingmed QVG Auto-4D). The method of disks was used for CMR LV volumes. Intra-observer, inter-observer, and inter-technique variability was assessed using intraclass correlation coefficient (CC), Pearson's CC, coefficients of variation, and Bland-Altman analysis.

Results

Feasibility was 98% for Teicholz Method and 3D-KR, 71% for Simpson's modified formula, and 73% for RT-3DE. We found globally poor correlation and agreement for volumes and EF between the different methods and MRI. The agreement was better when RV volumes were lower than 120mL/m2 (and thus, LV shape was less altered).

Conclusions

LV volumes and EFs cannot be measured accurately by echocardiography in patients with dilated right ventricles.

Le texte complet de cet article est disponible en PDF.

Plan


© 2014  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 107 - N° 8-9

P. 492 - août 2014 Retour au numéro
Article précédent Article précédent
  • Quality check of cardiac MRI exams for Fallot patients: Interest of a simple formula to detect invalid exams
  • K. Kecir, M. Beaumont, B. Chen, P.Y. Marie, J. Felblinger, L. Bonnemains
| Article suivant Article suivant
  • Radiation dose reduction in pediatric coronary CT: Assessment of effective dose and image quality
  • F. Raimondi, B. Habib Geryes, D. Khraiche, M. Bensemlali, P. Richard, N. Boddaert, D. Bonnet

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.