P52: Forensic alcohol analysis: Analytical requirements and problematics of interpretation - 28/06/14

Doi : 10.1016/S2352-0078(14)70113-1 
A.B. Ndjamaa 1, N. Abourejal 1, H. Attallah 2, H. Rezk-Kallah 1
1 Department of pharmacology and toxicology-university hospital, Oran, Algeria 
2 Regional forensic laboratory, Oran, Algeria 

Résumé

Introduction

In Algeria, The legal limit of BAC is 0,2g/L. This low rate justifies the use of sensitive and specific techniques to provide accurately results. The objectives are:

1
Compare results of BAC measured by an official method, gas chromatography (HS-CPG/FID) and an automatic method using an enzymatic test Emit®II Plus, designed for the determination of ethanol in serum or plasma, and applicated for analyzing whole blood pretreated.
2
Evoke the problematic of forensic interpretation of the alcohol concentrations perfomed for forensic porposes when the mesured rates are technically validated and correctly reported.

Methods

The procedure adopted to compare the two methods involves a duplicate analyzing of 11 whole blood samples loaded with pure ethanol, by enzymatic method after deproteinization and HS-CPG/FID without any pretreatment. The results are evaluated to estimate differences between the two methods. The postmortem samples of blood are analyzed by these methods in the context of toxicological expertise.

Results

The application of the test Emit®II Plus to whole blood after deproteination made of alcohol measurements by enzymatic method as reliable as those made by HS-CPG/FID with a coefficient of correlation equal 0.999. It is found that for concentrations lower than 0,55g/L, the results of both methods have a high level of similarity. From 0,55g/L, the enzymatic method tends to generate overestimation with an average of 0,13g/L. These overestimations are tolerable insofar as the subject remains under penalty of repression whatever the level of alcohol reached when the measured rate exceeds 0,2g/L. In the situation of analysis for alcohol in postmortem specimens, preanalytical error risks have been detected and complicated the interpretation of the alcohol concentrations.

Conclusion

This enzymatic method is an interesting alternative to the instrumental technique (GC) when the equipment is correctly calibrated and controlled and the results are correctly reported. However, the exclusive and uncritical use for forensic purposes is not recommended. Forensic toxicologists are called on to interpret the alcohol concentrations found in the specimens taking into account the risk of preanalytical errors.

Le texte complet de cet article est disponible en PDF.

© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 2S

P. S51 - juin 2014 Retour au numéro
Article précédent Article précédent
  • P51: Respiratory depression induced by a decoction of Papaver somniferum L. in two infants
  • I. Iken, A. Attari, A. Amarti, S. Achour
| Article suivant Article suivant
  • P53 Automated sample clean-up for a comprehensive forensic toxicology urine screening LC-MS/MS method
  • A. Taylor, M. Jarvis, D. Leach, C. Collins

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.