L’IRM 3 Tesla multi-paramétrique dans le staging du cancer prostatique en pratique courante - 20/02/14

Doi : 10.1016/j.purol.2013.09.005 
J.P. Largeron a, F. Galonnier a, N. Védrine a, A. Alfidja b, L. Boyer b, c, B. Pereira d, J.P. Boiteux a, c, J.L. Kemeny c, e, L. Guy a, , c
a Service d’urologie, hôpital Gabriel-Montpied, CHU de Clermont-Ferrand, 58, rue Montalembert, 63003 Clermont-Ferrand, France 
b Service de radiologie, hôpital Gabriel-Montpied, CHU de Clermont-Ferrand, 58, rue Montalembert, 63003 Clermont-Ferrand, France 
c Faculté de médecine, université d’Auvergne, 28, place Henri-Dunant, BP 38, 63001 Clermont-Ferrand cedex 1, France 
d Délégation recherche clinique et innovation, CHU de Clermont-Ferrand, villa annexe IFSI – rue Montalembert, 63000 Clermont-Ferrand, France 
e Département d’anatomopathologie, 58, rue Montalembert, 63003 Clermont-Ferrand, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 2
Vidéos 0
Autres 0

Résumé

But de l’étude

Déterminer la capacité de détection d’un adénocarcinome prostatique par une IRM 3Tesla multi-paramétrique avec antenne externe pelvienne, en comparaison de l’anatomopathologie chez des patients ayant subi d’une prostatectomie radicale.

Matériel et méthodes

Étude prospective de 30 mois, incluant 74 patients ayant tous un adénocarcinome prostatique diagnostiqué sur biopsies prostatiques, et tous éligibles à une prostatectomie radicale. Ils ont tous subi une IRM 3Tesla avec antenne externe pelvienne en séquences multi-paramétriques, comportant des séquences morphologiques et des séquences fonctionnelles de type perfusion et diffusion (avec calcul du coefficient apparent de diffusion). La glande prostatique était divisée en octants (8 zones), et trois critères précis ont été recherchés suivant ces zones (capacité de détection, capacité d’estimation du contact capsulaire (CC) et de l’effraction extra-capsulaire [EEC]). Une analyse a été réalisée en comparaison des pièces de prostatectomies radicales.

Résultats

Cinq cent quatre-vingt-douze octants ont été étudiés avec 124 tumeurs significatives (volume ≥0,1cm3). Pour la capacité générale de détection tumorale, l’IRM 3T avait une sensibilité, spécificité, VPP et VPN respectives de 72,3 %, 87,4 %, 83,2 % et 78,5 %. Cette imagerie avait un fort pouvoir prédictif négatif dans l’estimation du CC et de l’EEC avec des spécificités et des VPN respectives à 96,4 % et 95,4 % pour le CC, et 97,5 et 97,7 % pour l’EEC.

Conclusion

L’IRM 3Tesla multi-paramétrique nous est apparue être une technique d’imagerie fiable dans la détection du cancer prostatique en pratique courante et régulière. Avec un pouvoir prédictif négatif encourageant, l’estimation par une IRM 3T du CC et de l’EEC est à approfondir.

Niveau de preuve

3.

Le texte complet de cet article est disponible en PDF.

Summary

Objective

To analyse the detection ability of a multiparametric 3T MRI with phased-array coil in comparison with the pathological data provided by the prostatectomy specimens.

Methods

Prospective study of 30months, including 74 patients for whom a diagnosis of prostate cancer had been made on randomized prostate biopsies, and all eligible to a radical prostatectomy. They all underwent multiparametric 3T MRI with pelvic phased-array coil including T2-weighted imaging (T2W), dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) with an ADC mapping. Each gland was divided in octants. Three specific criteria have been sought (detection ability, capsular contact [CC] and extracapsular extension [ECE]), in comparison with the pathological data provided by the prostatectomy specimens.

Results

Five hundred and ninety-two octants were considered with 124 significant tumors (volume0.1cm3). The general ability of tumor detection had a sensitivity, specificity, PPV and NPV respectively to 72.3%, 87.4%, 83.2% and 78.5%. The estimate of the CC and ECE had a high negative predictive power with specificities and VPN respectively to 96.4% and 95.4% for CC, and 97.5 and 97.7% for ECE.

Conclusions

Multiparametric 3T MRI with pelvic phased-array coil appeared to be a reliable imaging technique in clinical and routine practice for the detection of localized prostate cancer. Estimation of the CC and millimeter ECE remains to be clarified, even if the negative predictive power for these parameters seems encouraging.

Le texte complet de cet article est disponible en PDF.

Mots clés : Cancer de la prostate, IRM, Bilan d’extension, Anatomopathologie

Keywords : Prostate cancer, MRI, Staging, Pathology


Plan


© 2013  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 24 - N° 3

P. 145-153 - mars 2014 Retour au numéro
Article précédent Article précédent
  • Editorial Board
| Article suivant Article suivant
  • AJUST : étude prospective et suivi à un an d’une série de 60 patientes
  • P. Debodinance

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.