S'abonner

Comparison of the Safety and Feasibility of Arrhythmia Ablation Using the Amigo Robotic Remote Catheter System Versus Manual Ablation - 12/02/14

Doi : 10.1016/j.amjcard.2013.11.030 
Tomás Datino, MD, PhD , Angel Arenal, MD, PhD, Mauricio Pelliza, MD, Jesús Hernández-Hernández, MD, Felipe Atienza, MD, PhD, Esteban González-Torrecilla, MD, PhD, Pablo Avila, MD, Loreto Bravo, MD, Francisco Fernández-Avilés, MD, PhD
 Department of Cardiology, Hospital General Universitario Gregorio Marañón, Madrid, Spain 

Corresponding author: Tel: (+34) 605135320; fax: (+34) 915868276.

Abstract

The aim of this study is to evaluate the safety and feasibility of using the Amigo Remote Catheter System (RCS) in arrhythmia ablation procedures. Because Amigo allows the physician to operate all catheter function outside of the radiation field, operator exposure time was also evaluated. This is a nonrandomized, prospective clinical trial conducted at 1 site (identifier: NCT01834872). The study prospectively enrolled 50 consecutive patients (mean age 59 ± 15 years, 72% men) with any type of arrhythmia (23 atrial fibrillation ablation, 12 common atrial flutters, 10 patients with other supraventricular tachycardia, 4 ventricular tachycardia, and 1 patient with palpitations with no arrhythmia induced) referred for catheter ablation, in which we used RCS. Fifty matched ablation procedures (mean age 57 ± 14 years, 70% men) performed during the same time period, without RCS, were enrolled into the control group. Acute ablation success was 96% with RCS and 98% in the manual group. In only 2 cases, the physician switched to manual ablation (1 ventricular tachycardia and 1 accessory pathway) to complete the procedure. There were no complications related to the use of RCS. No differences were observed in total procedure time, total fluoroscopy time, or total radiofrequency delivery compared with the manual group. In procedures performed with RCS, the operator's fluoroscopy exposure time was reduced by 68 ± 16%. In conclusion, arrhythmia ablation with RCS is safe and feasible. Furthermore, it significantly reduces operator's exposure to radiation.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 831 for disclosure information.


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 113 - N° 5

P. 827-831 - mars 2014 Retour au numéro
Article précédent Article précédent
  • Comparison of the Frequency of Atrial Fibrillation in Young Obese Versus Young Nonobese Men Undergoing Examination for Fitness for Military Service
  • Morten Schmidt, Hans Erik Bøtker, Lars Pedersen, Henrik Toft Sørensen
| Article suivant Article suivant
  • Two- and Three-Dimensional Speckle Tracking Analysis of the Relation Between Myocardial Deformation and Functional Capacity in Patients With Systemic Hypertension
  • Vera Celic, Marijana Tadic, Jelena Suzic-Lazic, Anita Andric, Anka Majstorovic, Branislava Ivanovic, Predrag Stevanovic, Olinka Iracek, Radisav Scepanovic

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.