Abstract

Objective

To define reference ranges for regional cerebral tissue oxygen saturation (crSO2) and regional cerebral fractional tissue oxygen extraction (cFTOE) during the first 15 minutes after birth in neonates requiring no medical support.

Study design

The crSO2 was measured using near infrared spectroscopy (Invos 5100 cerebral/somatic oximeter monitor; Somanetics Corp, Troy, Michigan) during the first 15 minutes after birth for term and preterm neonates. The near infrared spectroscopy sensor was placed on the left forehead. Peripheral oxygen saturation and heart rate were continuously measured by pulse oximetry, and cFTOE was calculated. Neonates were excluded if they required any medical support.

Results

A total of 381 neonates were included: 82 term neonates after vaginal delivery, 272 term neonates after cesarean delivery, and 27 preterm neonates after cesarean delivery. In all neonates, median (10th-90th percentiles) crSO2 was 41% (23-64) at 2 minutes, 68% (45-85) at 5 minutes, 79% (65-90) at 10 minutes, and 77% (63-89) at 15 minutes of age. In all neonates, median (10th-90th percentiles) cFTOE was 33% (11-70) at 2 minutes, 21% (6-45) at 5 minutes, 15% (5-31) at 10 minutes, and 18% (7-34) at 15 minutes of age.

Conclusion

We report reference ranges of crSO2 and cFTOE in neonates requiring no medical support during transition immediately after birth. The use of cerebral oxygenation monitoring and use of these reference ranges in neonates during transition may help to guide oxygen delivery and avoid cerebral hypo-oxygenation and hyperoxygenation.

Le texte complet de cet article est disponible en PDF.

Keyword : BW, CBF, CD, CDPreterm, CDTerm, cFTOE, crSO2, GA, HR, LMS, NIRS, rSO2, SpO2, VD, VDTerm


Plan


 Funded by Jubiläumsfond, Österreichische Nationalbank (13228). The authors declare no conflicts of interest.


© 2013  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 163 - N° 6

P. 1558-1563 - décembre 2013 Retour au numéro
Article précédent Article précédent
  • Timing of Interventions in the Delivery Room: Does Reality Compare with Neonatal Resuscitation Guidelines?
  • Lisa K. McCarthy, Colin J. Morley, Peter G. Davis, C. Omar F. Kamlin, Colm P.F. O’Donnell
| Article suivant Article suivant
  • Preterm Infant Linear Growth and Adiposity Gain: Trade-Offs for Later Weight Status and Intelligence Quotient
  • Mandy B. Belfort, Matthew W. Gillman, Stephen L. Buka, Patrick H. Casey, Marie C. McCormick

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.