S'abonner

Diagnostic performance of non–contrast-enhanced whole-heart magnetic resonance coronary angiography in combination with adenosine stress perfusion cardiac magnetic resonance imaging - 22/11/13

Doi : 10.1016/j.ahj.2013.08.018 
Tobias Heer, MD , Stephanie Reiter, MD, Berthold Höfling, MD, Günter Pilz, MD
 Agatharied Academic Teaching Hospital, University of Munich, Hausham, Germany 

Reprint requests: Tobias Heer, MD, Agatharied Academic Teaching Hospital of the University of Munich, Department of Cardiology, Norbert-Kerkel-Platz, D-83734 Hausham, Germany.

Résumé

Background

We sought to evaluate the diagnostic performance of 1.5-T non-contrast enhanced whole-heart magnetic resonance coronary angiography (MRCA) alone and in combination with adenosine stress cardiac magnetic resonance imaging (CMR-Perf). MRCA has been proposed to allow for detection of coronary artery disease (CAD). Yet, recent studies failed to show an incremental value of MRCA when added to CMR-Perf.

Methods

Non-Gadolinium 1.5-T contrast-enhanced, electrocardiogram-triggered, navigator-gated free-breathing MRCA was performed in 144 patients (pts) with suspected or known CAD. Accuracy of MRCA in detecting CAD was evaluated using X-ray coronary angiography as the reference. A novel algorithm was used to combine the results of MRCA and CMR-Perf.

Results

MRCA was diagnostic in 96/144 pts (67%) with regular breathing (mean age 62.5 ± 13); 77% of all coronary segments (939/1226) and 92% of segments suitable for percutaneous coronary intervention (792/866) were assessable. In 59 pts a novel algorithm to combine MRCA and CMR-Perf was performed with high diagnostic performance: accuracy, sensitivity, specificity, negative and positive predictive values were 91.5% (54/59; 95% CI, 84%-99%), 95.7% (22/23; 77-100), 88.9% (32/36; 74-96), 84.6% (22/26; 71-99), and 97.0% (32/33; 91-100). Compared to the combined use of CMR-Perf and late gadolinium enhancement, specificity with the novel algorithm significantly increased (P = .008).

Conclusion

MRCA has a high assessability in segments suitable for percutaneous coronary intervention in pts with regular breathing. The combined use of MRCA and CMR-Perf improved specificity for the detection of significant CAD.

Le texte complet de cet article est disponible en PDF.

Plan


 This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License, which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.


© 2013  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 166 - N° 6

P. 999-1009 - décembre 2013 Retour au numéro
Article précédent Article précédent
  • The Progression and Early detection of Subclinical Atherosclerosis (PESA) study: Rationale and design
  • Antonio Fernández-Ortiz, L. Jesús Jiménez-Borreguero, José L. Peñalvo, José M. Ordovás, Agustín Mocoroa, Leticia Fernández-Friera, Martín Laclaustra, Laura García, Jesús Molina, José M. Mendiguren, Beatriz López-Melgar, Vicente Martínez de Vega, Juan C. Alonso-Farto, Eliseo Guallar, Henrik Sillesen, James H.F. Rudd, Zahi A. Fayad, Borja Ibañez, Ginés Sanz, Valentín Fuster
| Article suivant Article suivant
  • Quantitative angiography and optical coherence tomography for the functional assessment of nonobstructive coronary stenoses: Comparison with fractional flow reserve
  • Stylianos A. Pyxaras, Shengxian Tu, Emanuele Barbato, Giulia Barbati, Luigi Di Serafino, Frederic De Vroey, Gabor Toth, Fabio Mangiacapra, Gianfranco Sinagra, Bernard De Bruyne, Johan H.C. Reiber, William Wijns

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.