S'abonner

A multicenter randomized comparison of paclitaxel-coated balloon catheter with conventional balloon angioplasty in patients with bare-metal stent restenosis and drug-eluting stent restenosis - 07/09/13

Doi : 10.1016/j.ahj.2013.07.002 
Seiji Habara, MD a, , Masashi Iwabuchi, MD b, Naoto Inoue, MD c, Shigeru Nakamura, MD d, Ryuta Asano, MD e, Shinsuke Nanto, MD f, Yasuhiko Hayashi, MD g, Nobuo Shiode, MD g, Shigeru Saito, MD h, Yuji Ikari, MD i, Takeshi Kimura, MD j, Joji Hosokawa, MD k, Masato Nakamura, MD l, Jun-ichi Kotani, MD m, Ken Kozuma, MD n, Kazuaki Mitsudo, MD a
a Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Japan 
b Kokura Memorial Hospital,Kitakyushu, Japan 
c Sendai Kousei Hospital, Sendai, Japan 
d Kyoto-Katsura Hospital, Kyoto, Japan 
e Sakakibara Heart Institute, Tokyo, Japan 
f Osaka University Graduate School of Medicine, Osaka, Japan 
g Tsuchiya General Hospital, Hiroshima, Japan 
h Shonan Kamakura General Hospital, Kamakura, Japan 
i Tokai University Hospital, Isehara, Japan 
j Kyoto University, Kyoto, Japan 
k Tokyo Heart Center, Tokyo, Japan 
l Toho University Ohashi Medical Center, Tokyo, Japan 
m National Cardiovascular Center, Suita, Japan 
n Teikyo University Hospital, Tokyo, Japan 

Reprint requests: Seiji Habara, MD, Department of Cardiology, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki-shi, Okayama 710-8602, Japan.

Résumé

Background

The aim of this study was to investigate the efficacy and safety of paclitaxel-coated balloon (PCB) for the treatment of the bare-metal stent restenosis (BMS-ISR) and drug-eluting stent restenosis (DES-ISR).

Methods

This study was a prospective, multicenter, randomized (2:1) trial conducted in 208 patients with 213 in-stent restenosis lesions (BMS-ISR: 123 lesions, DES-ISR: 90 lesions) at 13 centers in Japan. Patients were randomly assigned to a PCB group (137 patients with 142 lesions) or a conventional balloon angioplasty (BA) group (71 patients with 71 lesions). The primary end point was target vessel failure at 6-month follow-up.

Results

Clinical and angiographic follow-up 6 months after intervention was performed in 207 patients (99.5%) with 208 lesions (97.7%). Target vessel failure was noted in 6.6% of the PCB group and 31.0% of the BA group (P < .001). Recurrent restenosis occurred in 4.3% of the PCB group and 31.9% of the BA group (P < .001). Late lumen loss was lower in the PCB group than in the BA group (0.11 ± 0.33 mm vs 0.49 ± 0.50 mm, P < .001). In PCB-treated lesions, recurrent restenosis occurred in 1.1% of patients with BMS-ISR and in 9.1% of patients with DES-ISR (P = .04). Late lumen loss was lower in patients with BMS-ISR than in patients with DES-ISR (0.05 ± 0.28 mm vs 0.18 ± 0.38 mm, P = .03).

Conclusions

This randomized clinical study suggested that PCB provided much better clinical and angiographic outcomes than did conventional BA in patients with BMS-ISR and DES-ISR. Drug-eluting stent restenosis was associated with poorer outcomes compared with BMS-ISR after treatment with PCB.

Le texte complet de cet article est disponible en PDF.

Plan


 Randomized controlled trial registration no. UMIN000008681.


© 2013  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 166 - N° 3

P. 527 - septembre 2013 Retour au numéro
Article précédent Article précédent
  • Change in enrollment patterns, patient selection, and clinical outcomes with the availability of drug-eluting stents in the Bypass Angioplasty Revascularization Investigation 2 Diabetes trial
  • Binita Shah, Vankeepuram S. Srinivas, Jiang Lu, Maria M. Brooks, Eric R. Bates, Zoran S. Nedeljkovic, Jorge Escobedo, Gladwin S. Das, John J. Lopez, Frederick Feit
| Article suivant Article suivant
  • Bleeding after percutaneous coronary intervention in women and men matched for age, body mass index, and type of antithrombotic therapy
  • Gjin Ndrepepa, Stefanie Schulz, Franz-Josef Neumann, Robert A. Byrne, Petra Hoppmann, Salvatore Cassese, Ilka Ott, Massimiliano Fusaro, Tareq Ibrahim, Tomohisa Tada, Gert Richardt, Karl-Ludwig Laugwitz, Heribert Schunkert, Adnan Kastrati

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.